The calibration method coupled with registration errors of secondary imaging spectral polarimetric remote sensing system
Mingzhu Song, Lizhou Li
Key points
From the paper's conclusion- This method can effectively improve the calibration and inversion accuracy, providing a high-precision and reliable calibration framework for remote sensing applications of secondary imaging spectral polarimetric imaging systems.
Abstract
The secondary imaging optical configuration requires precise registration between the mosaic spectral filter array and the focal plane array of the polarization camera. Micrometer-level registration errors between these two components can cause spectral crosstalk among adjacent pixels, thereby reducing the accuracy of target characteristic measurements. To address this issue, this article proposes a polarimetric–radiometric joint calibration method coupled with registration errors. This method introduces registration errors into the mapping relationship between incident spectrum polarization information and imaging detector output. Based on this relationship, a system energy transfer and response model coupled with registration errors is established. Designs a calibration equation using spectral polarization superpixels as calibration units and provides its least squares solution method. Calibration and inversion experiments are conducted to compare and analyze the calibration matrix and inversion error under two conditions: ideal registration assumption and coupled registration error. The experimental results show that the relative error of radiance inversion is ≤ 1.81%, that of the degree of linear polarization is ≤ 2.69%, and the error of the angle of polarization is ≤ 1.1092°. This method can effectively improve the calibration and inversion accuracy, providing a high-precision and reliable calibration framework for remote sensing applications of secondary imaging spectral polarimetric imaging systems.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Scene-based semi-supervised algorithm for self-calibration of polarization imaging systems.Optics express · 2026
- Pixel-wise multi-error calibration and DoLP image recovery for low-extinction-ratio LWIR DoFP polarimetric cameras.Optics express · 2026
- Considerations for calibration of Stokes polarimeters.Journal of the Optical Society of America. A, Optics, image science, and vision · 2026
- Polarization Design and Calibration of AIMSResearch in Astronomy and Astrophysics · 2026
- Blind calibration of Linear Stokes imaging polarimeter based on trust region expansionJournal of Optics · 2026
- Design and development of a 1:1 configuration snapshot channeled Stokes spectropolarimeter.Applied optics · 2026