Current patterns and loss contributions in single-layer CORT cables carrying AC current
B Vanderheyden, J Dular, L Denis, S Elschner, C Geuzaine, M Wozniak, F Grilli
Key points
From the paper's conclusion- This study is carried out by means of an effective 2D model that uses a system of coordinates conforming with the helical structure of the cable.
Abstract
Conductor-on-round-tube (CORT) cables are a potential solution for carrying AC power in a small cross-section. Due to the geometry of the cable and the helical arrangement of the coated conductors (CC), the current follows a non-trivial pattern inside each CC. For instance, for the case of a single-layer cable, the current flow is mostly axial along the outer face of the conductors and mostly azimuthal along their inner face. Such a current distribution, known as the Garber current pattern , affects the transport AC losses. In numerical models, commonly adopted simplifications are either based on straight conductors or infinitely thin CCs. Such approaches neglect the Garber current pattern and thus misrepresent both the detailed current flow within the CC and the resulting 3D distribution of the fields. In this work, the detailed 3D current distribution in the CCs is investigated in a single-layer CORT cable, as a function of the cable geometrical parameters such as the conductor thickness, the pitch angle, and the gap between adjacent CCs. In particular, the impact of the Garber current pattern is studied on the two largest contributions to the AC losses, namely the surface losses and the edge losses. The detailed distribution of the currents in the CCs is examined and its relationship with the different AC loss mechanisms is established. This study is carried out by means of an effective 2D model that uses a system of coordinates conforming with the helical structure of the cable. The model uses a power-law electrical resistivity and for a power index n = 25 reproduces the AC losses predictions from critical state models to within 46% for vanishing gaps and less than 8% for straight cables. Calculated AC losses converge to the critical state predictions as the value of n is increased.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Impact of filamentary architecture on AC loss in coated conductor tapesSuperconductor Science and Technology · 2026
- Cable construction effects on the lateral forces and wakes of helically stranded cables under oblique inflowarXiv · 2026
- Compaction performance analysis of copper-sheath reinforced CORC cablesSuperconductor Science and Technology · 2026
- Analysis of AC losses and current distribution in parallel-wound HTS coils for superconducting motor armature windingsSuperconductor Science and Technology · 2026
- Dynamic Wind Loads on Double-Span Conductors and Their Influencing Factors: An Investigation Using Aeroelastic Wind Tunnel Tests and Finite Element AnalysisCivilEng · 2026
- AC loss analysis of distributed superconducting armature windings in electric motorsSuperconductor Science and Technology · 2026