Analysis of AC losses and current distribution in parallel-wound HTS coils for superconducting motor armature windings
Rui Li, Min Zhang, Oriol Fernández-Serracanta, Alexander Shchukin, Roshan Parajuli, Weijia Yuan, Francesco Grilli
Key points
From the paper's conclusion- We also compared the current distribution and AC losses of coils with different numbers of parallel conductors under different excitation conditions and clarified the effects of transport current and applied magnetic field on the losses.
Abstract
High temperature superconducting (HTS) coils composed of parallel conductors are being widely investigated to enhance the critical current in superconducting applications. Most studies on parallel-conductor wound coils focus on no-insulation coils under DC conditions, particularly their charging and discharging behaviour. In contrast, the parallel-wound coil considered in this work targets AC applications, such as armature windings in superconducting machines, for which the current distribution and AC loss characteristics remain insufficiently understood. Meanwhile, due to the electrical coupling at the HTS conductor terminals, the current distribution becomes a key issue, which is essential for evaluating the current-carrying capacity and quench limits of the coil. Due to the limited research on this type of coil for AC applications, three numerical methods were first employed to validate the accuracy of the model calculations, namely the weak form T-A formulation with Neumann boundary conditions, the T-A formulation with electrical circuit, and the H formulation, respectively. The three methods show strong agreement. Subsequently, the current distribution and AC losses of inductance-imbalanced and inductance-balanced coils were systematically compared under different excitation conditions. It is found that inductance imbalance induces circulating currents between parallel stacks, resulting in asymmetric current distribution, enhanced AC losses, and increased risk of local overcurrent, particularly under time-varying magnetic fields. In contrast, the inductance-balanced coil maintains more stable electromagnetic behaviour, where both the current distribution and AC losses exhibit weak sensitivity to variations in the externally applied parallel magnetic field. We also compared the current distribution and AC losses of coils with different numbers of parallel conductors under different excitation conditions and clarified the effects of transport current and applied magnetic field on the losses. These findings demonstrate the importance of inductance balancing for the reliable and safe operation of HTS AC power devices.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- AC loss analysis of distributed superconducting armature windings in electric motorsSuperconductor Science and Technology · 2026
- Electromagnetic modeling, loss analysis, and stress evaluation of parallel-wound no-insulation high-temperature superconducting magnetsSuperconductivity · 2025
- Electromagnetic-mechanical analysis of parallel-wound no-insulation HTS coils: current-imbalance-induced mechanical responseSuperconductor Science and Technology · 2026
- Digital compensation framework for transport AC loss measurements in multistack superconducting coilsSuperconductor Science and Technology · 2026
- Experimental and numerical study on current distribution in parallel co-wound no-insulation coilsSuperconductor Science and Technology · 2025
- Electromagnetic-mechanical coupling analysis of parallel-wound no-insulation high temperature superconducting coilsSuperconductor Science and Technology · 2026