Technical Innovation Assessment of SiC Varistors for Quench Protection of DEMO Toroidal Field Superconducting Coils
Simone Valenti, Matteo Manganelli, Tom Galvin, Dominic Coll, Pietro Zito, Alberto Ferro, Thomas Franke, Chiarasole Fiamozzi Zignani,
Key points
From the paper's conclusion- This highlights a dual requirement: the need for varistor material optimizations in the case of DEMO TFCs-specifically targeting a lower non-linearity parameter (β < 0.3)-, in order to fully realize the benefits of SiC varistors for high-energy fusion applications, and a potential reassessment of the conductor design, in terms of both copper stabilizer amount and cross-section geometry, to improve
Abstract
This paper investigates the feasibility and technical advantages of utilizing silicon carbide (SiC) varistors for the energy extraction systems of the toroidal field coils (TFC) in case of a quench in the present European DEMO fusion reactor design. Varistors offer a non-linear voltage-current response that provides faster discharge times and voltage limiting behavior compared to traditional linear resistors. Using the Metrosil 9000 series varistors as a baseline, comprehensive discharge simulations were conducted for both 8 and 16 Fast Discharge Unit (FDU) configurations. The study integrates electrical transient simulations to assess clamping voltages and advanced thermal modeling to evaluate the corresponding stress on the superconducting cables. Specifically, the quench propagation and the hotspot temperature evolution were investigated using both conservative adiabatic calculations and detailed transient thermal-hydraulic modeling (via the 4C code). Results indicate that, in normal operation mode, while voltage limits are successfully managed, the Joule integral limit is currently exceeded. Consequently, the thermal-hydraulic analysis reveals that jacket hotspot temperatures surpass the 150 K acceptance limit with varistor-based discharges, inducing higher thermal stresses than traditional resistors. This highlights a dual requirement: the need for varistor material optimizations in the case of DEMO TFCs-specifically targeting a lower non-linearity parameter (β < 0.3)-, in order to fully realize the benefits of SiC varistors for high-energy fusion applications, and a potential reassessment of the conductor design, in terms of both copper stabilizer amount and cross-section geometry, to improve current sharing during the discharge and conductor stability against small disturbances.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Design and experimental verification of the quench detection system for the CFETR central solenoid model coilSuperconductivity · 2025
- Design of dynamic and thermal stability test system for UHV switchgear based on 330kV grid power supplyJournal of Physics: Conference Series · 2026
- A Review of Degradation Mechanisms and Reliability Evaluation of ZnO Varistors for HVDC Surge ArrestersInternational Journal of Applied Ceramic Technology · 2026
- Short‐Circuit Current Behavior in High‐Voltage Disconnectors: A Critical Review of Analytical, Numerical, and Experimental InvestigationsRadio Science · 2026
- Seismic Performance and Reinforcement Strategies for ±600 kV Suspended Converter Valves — Part1: Seismic VulnerabilitiesSAE technical papers on CD-ROM/SAE technical paper series · 2026
- Voltage-Disturbance Identification and Fast Transfer Control of an IGCT-Based Hybrid Solid-State Transfer Switch.Sensors (Basel, Switzerland) · 2026