Dynamic evolution of pressure-dependent non-uniform turn-to-turn contact resistivity in no-insulation REBCO magnets: modeling and experimental validation
Shuowei Gao, Fang Liu, Huajun Liu, Shuai Hu, Ziming Wang, Z. Wang, Shengquan Xue, Wenzhe Hong,
Chinese Academy of Sciences · Institute of Plasma Physics
Key points
From the paper's conclusion- These results show that the charging behavior of the NI REBCO magnet in the high field is controlled by electromechanical coupling.
Abstract
Abstract The no-insulation (NI) magnets wound with REBCO coated conductors have thermal stability and quenching elasticity. This performance is driven by the current bypass on the interturn contacts. However, the resulting characteristic charging delay is controlled by complex electromechanical interactions in high magnetic fields, which are still difficult to predict. In this study, the contact resistivity of two ‘sandwich’ setups, namely ‘No-Insulation Contact’ and ‘Metal-Insulation (MI) Contact’, was investigated at 77 K and 4.2 K under pressure, specifically for copper-plated and copper-laminated tapes. A multi-exponential divergence model of contact resistivity with pressure is proposed to improve the fitting accuracy of the trend of contact resistivity with pressure. At the same time, the complete finite element method in the weak form of the T–A formulation is used to construct the simulation model of a large NI REBCO magnet based on a 2D axisymmetric coordinate system. The model directly calculates the inductance coupling through the magnetic vector potential, different from the field-circuit coupling model. This reduces the step of pre-calculating the huge mutual inductance matrix. Meanwhile, it incorporates electromechanical coupling by allowing the turn-to-turn contact resistivity (TTCR) to change dynamically in response to the instantaneous radial Lorentz force. It is verified on the ten-thousand-turn large-scale NI REBCO inserting magnet in the 35.1 T all-superconducting magnet system made by ASIPP. These results show that the charging behavior of the NI REBCO magnet in the high field is controlled by electromechanical coupling. Specifically, the Lorentz force alters the contact pressure distribution, leading to a spatially varying TTCR that determines the field stabilization time. This work provides key theoretical and model support for future electromagnetic–mechanical behavior prediction and quench robustness analysis of NI REBCO magnets.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Continuous evaluation of bending strain tolerance along a hundred meter class REBCO tapeSuperconductor Science and Technology · 2026
- Transverse-load-induced electromechanical degradation and damage evolution in TSSC REBCO cablesSuperconductor Science and Technology · 2026
- Experimental and numerical study on current distribution in parallel co-wound no-insulation coilsSuperconductor Science and Technology · 2025
- Numerical study of dynamic resistance and total loss in insulated and non-insulated HTS REBCO double-pancake coils at 77 KSuperconductivity · 2025
- Critical current distribution prediction in REBCO coated conductors via magnetization field and electromagnetic inversionSuperconductivity · 2025
- Numerical modelling of current non-uniformity in braided stacks of tapesSuperconductor Science and Technology · 2026