Minimally invasive quantification of [18F]MC225 PET using constrained simultaneous estimation of the input function.
Laura Providência, Joost F Somsen, Chris W Van Der Weijden, Pascalle Mossel, Giordana Salvi De Souza, Rudi A Dierckx, Gert Luurtsema, Adriaan A Lammertsma,
University Medical Centre Groningen, Hanzplein 1, Groningen, 9713 GZ, Netherlands. · University Medical Centre Groningen, Hanzeplein 1, Groningen, GR, 9713 GZ, Netherlands.
Key points
From the paper's conclusion- The findings of this study suggest that cSIME may help reduce the invasiveness of quantitative [18F]MC225 PET studies. The clinical relevance of the observed bias will ultimately depend on its magnitude relative to disease-related differences in kinetic parameters expected in patient populations.
Abstract
OBJECTIVE: [18F]MC225 is a PET radiotracer used to assess P-glycoprotein function at the bloodbrain barrier. [18F]MC225 PET quantification requires arterial catheterization to obtain the plasma input function, an invasive procedure. The simultaneous estimation of the input function (SIME) has been proposed as a technique for estimating the plasma input function, however, it requires at least one venous/arterial blood sample. Long axial field-of-view (LAFOV) PET scanners enable a variation of the SIME algorithm, the constrained SIME (cSIME), that incorporates information from whole-blood activity, potentially eliminating the need for blood sampling. In this study, we evaluated the feasibility of cSIME for quantifying the [18F]MC225 in the brain using a clinical dataset. APPROACH: Dynamic data from seven subjects scanned on a LAFOV PET system following injection of [18F]MC225 were included. The constrained SIME method was used to estimate the plasma input function of each subject. A whole-blood input function extracted from the ascending aorta was used as the initial estimate, and multiple brain regions were simultaneously fitted to estimate the parameters required to convert the whole-blood input function into a plasma input function. Volume of distribution (VT) values were calculated using both the ground-truth and cSIME-estimated plasma input functions with a reversible two-tissue compartment model. MAIN RESULTS: Without a blood sample,VTestimates using the cSIME plasma input function resulted in relative differences ranging between approximately -26% and 11% compared to theVTestimates obtained with the measured plasma input function. Incorporating one blood sample as anchor at 60 minutes decrease these relative differences to 11%. SIGNIFICANCE: The findings of this study suggest that cSIME may help reduce the invasiveness of quantitative [18F]MC225 PET studies. The clinical relevance of the observed bias will ultimately depend on its magnitude relative to disease-related differences in kinetic parameters expected in patient populations.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- EXPRESS: Blood-free full quantification of dynamic TSPO PET imaging with [11C]PBR28Journal of Cerebral Blood Flow & Metabolism · 2026
- EXPRESS: Quantitative Physiological Modelling of Cerebral Blood Flow with an Outflow Model in [18F]FDG and [15O]H2O PET Imaging.Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism · 2026
- A reference-based approach using whole-brain segmentation for estimating blood activity concentration in CBV quantification.Annals of nuclear medicine · 2026
- Non‐Contrast Assessment of Blood–Brain Barrier Permeability to Water: Improved Signal Modeling and Data AcquisitionMagnetic Resonance in Medicine · 2025
- From 18F‑MC225 to Conformationally Free Derivatives.ACS omega · 2026
- Single-sample-calibrated image-derived pharmacokinetics of the PD-L1-targeted tracer [68Ga]Ga-NOTA-SNA002 using total-body PET: Beyond conventional venous blood sampling.European journal of nuclear medicine and molecular imaging · 2026