Single-sample-calibrated image-derived pharmacokinetics of the PD-L1-targeted tracer [68Ga]Ga-NOTA-SNA002 using total-body PET: Beyond conventional venous blood sampling.
Lichao Zhang, Yunze Xie, Wenxin Tang, Runjun Yang, Jonathan Vigne, Lorenzo Nardo, Florent L Besson, Axel Rominger,
Shanghai Institute of Medical Imaging, Shanghai, 200032, China. · Department of Nuclear Medicine, CHU de Caen Normandie, Normandie Université, UNICAEN, 14000, Caen, France.
Key points
From the paper's conclusion- Total-body dynamic PET imaging with a single-sample calibration provides PK data comparable to conventional venous blood sampling while simultaneously characterizing tissue kinetic profiles throughout the body. Additionally, these kinetic parameters may offer complementary value for the stratification of lesion-level PD-L1 expression and the preliminary assessment of immunotherapy response.
Abstract
PURPOSE: To evaluate the feasibility and additional value of total-body PET image-derived pharmacokinetics over venous blood-sampling method in investigating non-tumor tissue and lesion kinetics of the PD-L1-targeted tracer [68Ga]Ga-NOTA-SNA002 in patients with malignant tumors. METHODS: Patients with solid tumors underwent a 60-min dynamic total-body PET acquisition following [68Ga]Ga-NOTA-SNA002 injection, and a 20-min static scan at 120 min post-injection, accompanied by serial venous blood sampling. Systemic PK parameters were estimated via noncompartmental analysis based on time-concentration curves from venous blood sampling and image-derived venous vascular regions using a single-sample calibration, and the PK parameters obtained from the two methods were compared. To characterize kinetic parameters, time-activity curves (TACs) of non-tumor tissues and lung lesions were fitted using compartment models. Lesions' kinetic metrics and standardized uptake value (SUV) were compared after stratification by tumor proportion score (TPS; < 50% vs. ≥ 50%). RESULTS: Image-derived maximum concentration (Cmax) was significantly higher and time to Cmax (Tmax) was significantly shorter than those obtained from venous blood sampling. No significant between-method differences were observed for the remaining PK parameters, except SVC-derived clearance (CL; 2.35 ± 0.69 vs. 2.69 ± 0.90 L/h, P = 0.016). The relative differences were within 18% for right atrium (RA) and within 19% for superior vena cava (SVC) for these parameters. Lesions with high TPS (≥ 50%) demonstrated significantly elevated K1 (0.51 ± 0.17 vs. 0.11 ± 0.09 mL/cm3/min, P = 0.009) and k2 (6.06 ± 1.76 vs. 2.19 ± 1.60 min-1, P = 0.009) compared to those with low TPS (< 50%). Additionally, dynamic [68Ga]Ga-NOTA-SNA002 PET provided information on tracer retention in non-tumor tissues and lesions. CONCLUSION: Total-body dynamic PET imaging with a single-sample calibration provides PK data comparable to conventional venous blood sampling while simultaneously characterizing tissue kinetic profiles throughout the body. Additionally, these kinetic parameters may offer complementary value for the stratification of lesion-level PD-L1 expression and the preliminary assessment of immunotherapy response. CLINICAL TRIAL REGISTRATION: This phase I clinical trial was approved by the National Medical Products Administration of China and was registered at www.chinadrugtrials.org.cn (registry number: CTR20232251).
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- 68Ga-NK224 PET/CT Reveals Intra- and Intertumoral Heterogeneity of PD-L1 in Non-Small Cell Lung Cancer.Radiology · 2026
- 18F-BMS-986192 PET to Predict Durable Response to Nivolumab in NSCLC: A Novel Approach Beyond PD-L1 Immunohistochemistry.Journal of nuclear medicine : official publication, Society of Nuclear Medicine · 2026
- IMG-80 Is One Biopsy Enough? Quantitative Novel PD-L1 PET/CT Unmasks Tumor Heterogeneity in Head and Neck Squamous Cell CarcinomaNeuro-Oncology · 2026
- PD-L1 PET/CT imaging with 18F-BMS-986,229 and 18F-BMS-986,192 in patients with advanced-stage non-small cell lung cancer.European journal of nuclear medicine and molecular imaging · 2026
- Programmed death ligand 1 (PD-L1) PET/CT imaging to evaluate tumour saturation during atezolizumab treatment.British journal of cancer · 2026