Tensor-Driven Spectral CT Reconstruction via Noise-Adaptive Channel Weighting and Deterministic Block Matching.
Bahareh Morovati, Changsheng Fang, Shuo Han, L I Zhou, Shuyi Fan, Y U Shi, Hengyong Yu
Department of Electrical and Computer Engineering, University of Massachusetts Lowell, Lowell, MA 01854, USA.
Key points
From the paper's conclusion- Second, we employ deterministic hierarchical block clustering with Ward linkage for robust block matching, eliminating the initialization sensitivity of conventional k-means while improving grouping quality and improving the balance between detail preservation and noise suppression.
Abstract
Photon-counting computed tomography (PCCT) enables revolutionary spectral imaging by capturing energy-resolved data in a single scan, offering unprecedented material discrimination and diagnostic capabilities. However, photon count limitations in individual energy channels result in severe noise amplification, degraded spatial resolution, and loss of fine anatomical details. Those challenges intensify in low-dose and sparse-view clinical protocols. To overcome these fundamental limitations, we propose a novel reconstruction framework that synergistically integrates three key innovations. First, we introduce an enhanced multi-metric channel weighting that automatically estimates signal-to-noise ratio per energy channel and dynamically prioritizes high-quality channels through multi-metric analysis by combining gradient magnitude, entropy, and spatial-spectral energy. Second, we employ deterministic hierarchical block clustering with Ward linkage for robust block matching, eliminating the initialization sensitivity of conventional k-means while improving grouping quality and improving the balance between detail preservation and noise suppression. These innovations are seamlessly integrated within a tensor decomposition framework that takes advantage of cross-channel correlations through low-rank factorization and enhanced sparsity constraints. Comprehensive validation on challenging extremity datasets acquired with a MARS PCCT scanner demonstrates substantial improvements in edge sharpness, noise suppression, and overall reconstruction quality compared with the conventional methods. Under 150 projection acquisition, the proposed framework achieves a SSIM of 0.9640±0.0198, PSNR of 36.35±0.0693 dB, and FSIM of 0.9698±0.1043 for Energy Channel 4. Our framework addresses critical reconstruction challenges in clinical PCCT, paving the way for robust multi-energy imaging.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Photon-Counting Computed Tomography in the Era of Precision Medicine: Technological Advances, Artificial Intelligence Integration, and Multidisciplinary Clinical ApplicationsInternational Science Journal · 2026
- Understanding Photon-Counting CT: Physics, Detector Technology, and Image Reconstructions.Sensors (Basel, Switzerland) · 2026
- Self-Adaptive Ring Artifact Reduction Method for Spectral Photon Counting CT.IEEE transactions on medical imaging · 2026
- OA-Recon: An Online Adaptive Reconstruction Framework for Sparse-View Multi-Energy CT.IEEE transactions on medical imaging · 2026
- Unified Projection-Domain Material Decomposition for Energy-Integrating and Photon-Counting CT.ArXiv · 2026
- Comparison of spectral performance of three dual-energy CT scanners equipped with a deep-learning image reconstruction algorithm and one photon counting CT scanner: A phantom studyDiagnostic and Interventional Imaging · 2025