Analysis of computational methods used to optimize transmission x-ray targets for 100- to 500-kV x-ray tubes.
Benjamin Abraham Insley, Mohammad R Salehpour, Dirk Alan Bartkoski
Radiation Physics, The University of Texas MD Anderson Cancer Center, 1400 Pressler St, Houston, Houston, Texas, 77030-4000, United States. · Department of Radiation Physics MD Anderson Cancer Center, University of Texas System Cancer Center, Unit 94, 1515 Holcombe Blvd, Houston, Texas, 77030, United States.
Key points
From the paper's conclusion- The data presented here represent an important resource in transmission X-ray target modeling.
Abstract
While the process of designing a low-to-medium energy transmission X-ray target follows a similar general approach throughout the literature, the specific methodology can vary substantially. The goal of this study was to determine the sensitivity of X-ray target optimization to different methods of X-ray quantification and temperature modeling. Approach: Ultrathin (1.5- to 90-μm) tungsten transmission X-ray targets were modeled in TOPAS (v.3.8) and bombarded with electrons at energies of 100-500 keV. Simulations were run to compare the optimal target thickness according to various tallies of the emitted X-ray field, including primary beam fluence, energy fluence, air KERMA, dose to water in air, or dose to water at depth in phantom. The optimized targets for each energy were simulated again to calculate the spatial distribution of heat deposited within the target and the attached diamond or copper window. Finally, COMSOL Multiphysics® was used to compare temperature calculations with a volumetric heat source model versus a simplified surface heat source model. Main results: The target thickness optima varied significantly across the different X-ray quantities; whereas some metrics favored very thin targets (<10 μm) for higher, low-quality X-ray output, others favored thicker targets (>50 μm) weighted towards higher-energy X-ray fields. Heat calculations in the optimized targets showed that single-scattering Monte Carlo produced a greater energy deposition tally compared to multiple-scattering models. Lastly, finite element temperature calculations did not change significantly between the full spatial heat deposition model and the simplified surface heat source model. Significance: This study demonstrates the importance of selecting the proper quantity for target optimization to ensure the most translatable results for the device's intended use. This work also shows that temperature modeling can be greatly simplified to accelerate the design process while maintaining computational accuracy. The data presented here represent an important resource in transmission X-ray target modeling.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Generalized multi-energy model for computing radiation treatment parameters on image domain and automated model-selection framework.World journal of radiology · 2026
- DNA double-strand break yield and radiation quality of diagnostic X-rays from 40 to 120 kV: a scale-resolved microdosimetric and track-structure studybioRxiv · 2026
- Simulations on Scintillator Thicknesses for Bone Mineral Density Measurement Based on Dual-Layer Flat-Panel Detectors.Diagnostics (Basel, Switzerland) · 2026
- Monte Carlo Predictions of Radiation Damage in the ISIS TS1 TargetJournal of Physics: Conference Series · 2026
- Monte Carlo investigation of anode-filter combinations on X-ray spectra in conventional radiology using PHITS.Physical and engineering sciences in medicine · 2026
- Patient-Specific Stopping Power Calibration of Treatment Planning X-Ray CT Using Integrated Depth-Dose Profiles Acquired by Proton Transmission Imaging - A Feasibility Study.Physics in medicine and biology · 2026