Detector nonlinearity in measuring the bone mineral density based on neural networks.
Eunae Lee, Dong Sik Kim
Neuroscience Research Institute, Seoul National University Medical Research Center, 103 Daehak-ro, Jongno-gu, Seoul, 03080, Korea (the Republic of). · Division of Semiconductor and Electronics Engineering, Hankuk University of Foreign Studies, 81, Oedae-ro, Mohyeon-eup, Cheoin-gu, Yongin-si, 17035, Korea (the Republic of).
Key points
From the paper's conclusion- This approach enables the implementation of a simple, robust bone densitometry system that effectively bypasses complex detector nonlinearity issues, offering a highly accurate and cost-effective alternative to traditional dual-energy x-ray absorptiometry (DXA) scanning systems.
Abstract
A dual-layer flat panel detector (DFD) allows for the acquisition of dual-energy images with a single x-ray exposure without scanning. In this paper, we aim to perform noise sensitivity analyses on a single-shot approach using DFD in measuring bone mineral density (BMD) and propose a method for calculating BMD using features acquired from a nonlinear response detector without a nonlinearity correction scheme. Approach. We evaluate the condition numbers of the BMD estimate functions and observe the mean squared error (MSE) for ranges of additive and multiplicative errors to compare with a dual-shot FPD approach. To accurately describe the BMD surface, we use a fully connected neural network (FCNN) model instead of the conventional multiple regression model. We conduct experiments to observe and model the nonlinear response of DFD, followed by simulations based on a BMD model with nonlinear intensities. Main results. Extensive simulations demonstrate that BMD measurements using nonlinear intensities without correction outperform methods that calculate BMD after nonlinear correction. Furthermore, the approach based on the FCNN model significantly outperforms the conventional approach using a multiple regression model. Significance. This approach enables the implementation of a simple, robust bone densitometry system that effectively bypasses complex detector nonlinearity issues, offering a highly accurate and cost-effective alternative to traditional dual-energy x-ray absorptiometry (DXA) scanning systems.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Simulations on Scintillator Thicknesses for Bone Mineral Density Measurement Based on Dual-Layer Flat-Panel Detectors.Diagnostics (Basel, Switzerland) · 2026
- Diagnostic Performance of Radiofrequency Echographic Multi Spectrometry Compared with Dual-Energy X-Ray Absorptiometry: A Real-World Study.Diagnostics (Basel, Switzerland) · 2026
- Site-Specific Material Decomposition Versus Universal Z-Effective: Optimizing Opportunistic Bone Mineral Density Screening via Dual-Energy CT.Journal of imaging · 2026
- Opportunistic application of machine learning for bone health stratification in type 2 diabetes mellitus.Frontiers in endocrinology · 2026
- AI-powered nonlinear optical imaging reveals protein spatial homogenization as an indicator of impaired bone quality in type 2 diabetesOpto-Electronic Advances · 2026
- Automated opportunistic screening for low bone mineral density using routine CT brain imaging.Frontiers in radiology · 2026