Site-Specific Material Decomposition Versus Universal Z-Effective: Optimizing Opportunistic Bone Mineral Density Screening via Dual-Energy CT.
Stefano Piscone, Luca Pio Stoppino, Martina Matera, Benedetta Di Millo, Giorgia Schiraldi, Paola Milillo, Roberta Vinci, Luca Macarini
Department of Medical & Surgical Sciences, Section of Diagnostic Imaging, University of Foggia, 71122 Foggia, Italy.
Key points
From the paper's conclusion- In conclusion, opportunistic DECT screening requires anatomically tailored BMP selection or, alternatively, Z-Effective alone as a unified spectral parameter to achieve reliable, accurate BMD evaluation during routine CT acquisitions.
Abstract
Dual-energy computed tomography (DECT) represents a high-precision tool for opportunistic bone mineral density (BMD) assessment, yet optimal algorithmic standardization across anatomical sites remains debated. This opportunistic study evaluated 60 postmenopausal female patients who underwent both dual-energy X-ray absorptiometry (DXA) and contrast-enhanced spectral DECT (80/140 kVp) within a 6-month interval. Quantitative trabecular measurements were obtained at the femoral neck and lumbar spine (L1-L4) across five distinct Base Material Pairs (BMPs) and Effective Atomic Number (Z-Effective). Material decomposition revealed significant anatomical site dependency: fat-based pairs demonstrated superior correlation with DXA BMD at the femoral neck (Calcium-Fat: ρ = 0.703; p ≤ 0.001), whereas water-based pairs performed best in the cellular, red-marrow-rich lumbar spine (CaOxMono-Water: ρ = 0.525; p ≤ 0.001). In contrast, Z-Effective functioned as a robust biomarker, maintaining significant positive linear correlations across both the proximal femur (ρ = 0.652; p ≤ 0.001) and lumbar spine (ρ = 0.489; p ≤ 0.001). Multivariable linear regression demonstrated severe multicollinearity between site-matched BMPs and Z-Effective (VIF > 5.0), confirming they capture identical physical mineral depletion. In conclusion, opportunistic DECT screening requires anatomically tailored BMP selection or, alternatively, Z-Effective alone as a unified spectral parameter to achieve reliable, accurate BMD evaluation during routine CT acquisitions.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Development of a One-Stop Bone Mineral Density Estimation Model Based on Dual-Energy CT with Quantitative Computed Tomography as the Reference Standard.Diagnostics (Basel, Switzerland) · 2026
- An energy-difference indicator for improved quantification of bone mineral density using dual-energy CT.Journal of the Royal Society, Interface · 2026
- Complementing Bone Mineral Density Assessment: DXA-Based Radiomics for Vertebral Evaluation in Older Adults.Medicina (Kaunas, Lithuania) · 2026
- The association between bone density evaluated on CT or MRI versus the gold standard dual-energy X-ray absorptiometry (DEXA) in the lumbar spine and hip: a meta-analysis.Brain & spine · 2026
- Simulations on Scintillator Thicknesses for Bone Mineral Density Measurement Based on Dual-Layer Flat-Panel Detectors.Diagnostics (Basel, Switzerland) · 2026
- Opportunistic Osteoporosis Screening Using CT-Derived Volumetric Bone Mineral Density Reference Curves.Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research · 2026