Hierarchical localisation of position of screw metallic internal component
Xueling Ji, Jiamin Ye, Yanzhe Gao, Chao Wang, Wuqiang Yang
Key points
From the paper's conclusion- In screw-conveying systems, the rotating screw metallic internal component (SMIC) causes electric-field distortion, which is position-dependent.
Abstract
Image reconstruction for electrical capacitance tomography (ECT) requires sufficient measurements and accurate sensitivity modelling. In screw-conveying systems, the rotating screw metallic internal component (SMIC) causes electric-field distortion, which is position-dependent. As a result, the sensitivity distribution depends on the position of SMIC. Because this effect is reflected in the real-time capacitance measurements, these measurements can be used for frame-wise SMIC localisation for reconstruction. In this study a hierarchical localisation framework is investigated for estimating the position of SMIC from single-frame ECT measurements. A three-stage hierarchical model is developed to characterise the relationship between the position of SMIC and capacitance measurements using SMIC-sensitive features of capacitance. Using adjacent-electrode-pair measurements that are highly sensitive to the grounded SMIC, the estimate from coarse sector identification to fine angular estimation is progressively refined. Simulation results under different flow patterns show zero localisation error for both noisefree data and data contaminated by Gaussian white noise with a signal-to-noise ratio (SNR) matching the average SNR of the adjacent-electrode-pair measurements in the experiments. When Gaussian white noise with an SNR matching the average SNR of all experimental measurements is added, the absolute error remains below 2°, with a mean absolute error of 0.5°. Experimental results show an absolute error within 4° and a mean absolute error of 1.67°, despite additional manual positioning errors. The proposed method achieves accurate and robust SMIC localisation using only single-frame ECT measurements, without additional position sensors or reliance on inter-frame continuity, and lays the foundation for ECT in screw-conveying systems with SMIC.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Rotating electrode electrical capacitance tomography system.The Review of scientific instruments · 2026
- Electronically Rotated Electrical Capacitance Tomography Sensing and Image Reconstruction Based on Transformer Model.Sensors (Basel, Switzerland) · 2026
- Spatiotemporal Modeling of Impedance Degradation and Compensation of ERT Electrodes for Target Reconstruction.Sensors (Basel, Switzerland) · 2026
- Gaussian decomposition of EIT reconstructions with different inclusion geometries.Physiological measurement · 2026
- Interface-Sensitive Electrical Capacitance-Ratio Tomography for Supercavity Profile Reconstruction in Open DomainIEEE Transactions on Instrumentation and Measurement · 2026