Autofluorescence imaging-based nondestructive monitoring of latent patterns in photolithography
Jeonggeun Song, Jinsu Choi, Soonyong Kwon, Won Seok Chang, Hongki Yoo
Key points
From the paper's conclusion- We propose an autofluorescence-imaging-based monitoring method that operates immediately after UV exposure, using excitation wavelengths spectrally separated from the exposure wavelength, and establish its performance as a measurement.
Abstract
Nondestructive, post-exposure monitoring of latent photoresist patterns remains challenging because conventional metrology relies on post-development inspection, making it difficult to attribute deviations to exposure conditions. We propose an autofluorescence-imaging-based monitoring method that operates immediately after UV exposure, using excitation wavelengths spectrally separated from the exposure wavelength, and establish its performance as a measurement. To identify a suitable monitoring wavelength, latent patterns were imaged at four excitation wavelengths. Among the wavelengths tested, 561 nm provided the most stable latent-pattern signal, with only a −3.1 % change after 30 s of continuous excitation, whereas shorter-wavelength excitation caused unintended additional exposure or substantial photobleaching. The autofluorescence contrast increased nonlinearly with exposure dose and gradually approached saturation, as described by a model derived from depth-integrated photochemical conversion. Inverting the fitted response estimated the delivered dose with 6–11 % RMS error (leave-one-out), and retained sensitivity above the dose to clear, where the developed topography saturated and post-development inspection became insensitive to over-dose. In two independently conducted exposure experiments, no systematic monitoring-induced change in the developed geometry was detected, and the minimum detectable dose was 9.7 mJ/cm² at 3σ. This label-free approach enables pre-development latent-pattern imaging and quantitative dose monitoring for microscale maskless lithography and process development.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- An Open-Source, Excitation-Resolved UV-NIR Imaging Platform for Bioluminescence, Luminescence-Decay, and Chemical Discrimination Measurements.bioRxiv : the preprint server for biology · 2026
- Synchronized Fluorescence Emission and UV–Vis Absorption Wavelength Shift Sensing for Trace Moisture in Highly Polar Aprotic SolventsAdvanced Optical Materials · 2026
- Mitigating X-ray-Induced Damage in CD-SAXS Metrology of EUV Resists.ACS applied materials & interfaces · 2026
- Designing Stable Photoresists Using Polymers With Photoinduced Reversible Solid-to-Liquid Transitions for Nanoimprint Lithography.Small (Weinheim an der Bergstrasse, Germany) · 2026
- Traceable Measurement of Peak Irradiance and Fluence Rate Enables Accurate Dose Determination of Pulsed Xenon Ultraviolet Disinfection.Environmental science & technology · 2026
- Label- and Slide-Free Multispectral Quantitative Epi-Illumination Deep-Ultraviolet Microscopy.BME frontiers · 2026