10-kHz coherent anti-stokes Raman spectroscopy thermometry in an arc heater
Xuteng Zhang, Xiaohui Dai, Dongdi Zhao, Yingjie Song, Jiangbo Peng, Zhen Cao, Xinguang Luo, Chaobo Yang,
Key points
From the paper's conclusion- Based on a 10-kHz Nd:YAG pulse-burst laser and a non-collinear optical parametric oscillator(NOPO), we successfully developed a 10-kHz broadband coherent anti-Stokes Raman spectroscopy (CARS) system for ro-vibrational temperature measurements in non-equilibrium flow.
Abstract
The complexity of high-temperature non-equilibrium flow leads to significant limitations of existing computational fluid dynamics (CFD) models.To further refine these models, there is a pressing need to acquire ro-vibrational temperature data in non-equilibrium flows, which serves to characterize the molecular population distribution. Based on a 10-kHz Nd:YAG pulse-burst laser and a non-collinear optical parametric oscillator(NOPO), we successfully developed a 10-kHz broadband coherent anti-Stokes Raman spectroscopy (CARS) system for ro-vibrational temperature measurements in non-equilibrium flow. The NOPO enables tunable, broadband, pulse-burst laser output, delivering a maximum single-pulse energy of up to 22.61 mJ with the laser bandwidth of up to 382 $\rm{cm^{-1}}$. We employed the unstable-resonator spatially enhanced detection CARS technology, which could reduce the interference from strong vibrations in the real-world engineering environment on CARS signal measurements. The sub-frame burst imaging mode of a high signal-to-noise-ratio, low-frame-rate EM-CCD camera was utilized to meet the demands of 10kHz CARS signal acquisition. High‑repetition‑rate, single‑shot, high signal-to-noise-ratio CARS spectral measurements were realized and highly time-resolved ro-vibrational temperatures of $\rm {N_2}$ were obtained in an arc heater.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Vibrational temperature measurement of diatomic nitrogen using femtosecond/picosecond coherent anti-Stokes Raman scattering in the ONR-UTA arc-jet facilityExperiments in Fluids · 2026
- Dual-band scanned-wavelength infrared laser-induced fluorescence of CO with time-domain modeling for 1 kHz thermometry.Optics express · 2026
- High-speed mass flux measurements using mid-infrared electro-optic dual-comb spectroscopy.Applied optics · 2026
- Raman Thermometry of Confined Gas Milli-Flows.Sensors (Basel, Switzerland) · 2026
- Dual-comb spectroscopy for in-situ temperature measurements of gas-filled hollow-core fibers.Optics letters · 2026
- Dual-comb spectroscopy for spatially resolved hydrogen combustion diagnostics over a wide temperature range.Optics express · 2026