Measurement Science and TechnologyOpen accessComputer science

Uncertainty-aware offline-calibrated sequential sparse-frequency electrochemical impedance spectroscopy for lithium-ion battery health estimation

Zhen Tao, Mingke Yang, Kye Yak See

Nanyang Technological University

Key points

From the paper's conclusion
  • Thus, the protocol is not claimed to dominate baselines in point accuracy; its contribution is an auditable sparse-EIS measurement workflow that reports selected frequencies, modelled acquisition cost, SOH error, interval width and empirical coverage together.

Abstract

Abstract Electrochemical impedance spectroscopy (EIS) is a sensitive diagnostic measurement for lithium-ion batteries, but traditional full-spectrum acquisition is often too slow for practical battery-management use because low-frequency points dominate measurement time. This paper develops sparse-frequency EIS as an uncertainty-aware, offline-calibrated sequential measurement protocol for state-of-health (SOH) estimation. Candidate frequencies are selected by balancing expected SOH-error reduction, 90% prediction-interval width and modelled frequency-dependent acquisition cost. The validation is retrospective: stored full-spectrum EIS archives are masked so that revealing one archived frequency represents a prospective sparse-frequency measurement. On Dataset A, the Proposed protocol uses six frequencies and obtains 2.12% MAE, 0.80 empirical interval coverage and 0.145% modelled relative acquisition cost. On Dataset B, it uses three frequencies and obtains 1.52% MAE, 0.95 coverage and 0.426% cost. Dataset C shows the deployment trade-off most clearly: sparse frequencies calibrated on representative source cells remain close to full-spectrum EIS for point estimation (1.12% versus 1.09% MAE, 0.43% cost), but uncertainty transfer fails, with empirical 90% interval coverage of only 0.57. Objective ablation shows the cost-accuracy compromise: setting lambda_w = lambda_t = 0 improves Dataset C MAE to 0.98% but increases cost to 12.18%. Thus, the protocol is not claimed to dominate baselines in point accuracy; its contribution is an auditable sparse-EIS measurement workflow that reports selected frequencies, modelled acquisition cost, SOH error, interval width and empirical coverage together. The main limitation is uncertainty transfer under domain shift, so conformal intervals should be treated as empirical reliability outputs rather than universal guarantees.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers