Effect of Body Position on Chest Compression Quality During CPR in an Obesity Simulation Model: A Randomized Crossover Trial.
Aleksander Mickiewicz, Michał Czapla, Łukasz Lewandowski, Raúl Juárez-Vela, Jacek Smereka
Department of Emergency Medical Service, Faculty of Nursing and Midwifery, Wroclaw Medical University, Wroclaw, Poland. · Department of Biochemistry and Immunochemistry, Wroclaw Medical University, Wroclaw, Poland.
Key points
From the paper's conclusion- Simulated obesity markedly impairs chest compression quality despite increased paramedics' effort, likely due to biomechanical constraints. The 10 cm elevation of the paramedic did not improve compression effectiveness. These findings highlight the need for targeted strategies and further prospective clinical studies to optimize CPR in patients with obesity.
Abstract
OBJECTIVES: Obesity may impair the effectiveness of cardiopulmonary resuscitation (CPR) through biomechanical constraints; however, its impact on chest compression quality and the role of simple ergonomic modifications remain unclear. This study aimed to evaluate the effect of simulated obesity and body position on CPR performance. METHODS: This prospective randomized crossover simulation trial included 60 paramedics. Each participant performed 2-min chest compression sessions under three conditions: standard manikin, obesity-simulation manikin, and obesity-simulation manikin with the paramedic elevated on a 10 cm pad. Primary outcomes were compression depth, rate, and complete chest recoil. The secondary outcome was perceived exertion. Data were analyzed using linear mixed-effects models. The trial was prospectively registered (ACTRN12625000658415). RESULTS: Compression depth was significantly lower in both obesity-simulation conditions than in the standard condition, with adjusted mean differences of 17.83 mm (95% CI 15.95-19.71) and 18.44 mm (95% CI 16.58-20.30), respectively (both p < 0.001). The median percentage of compressions with adequate depth was 98.0% in the standard condition and 0.0% in both obesity-simulation conditions (both p < 0.001). Compression rate differed only modestly across conditions. Mean compression force and the Borg Rating of Perceived Exertion were significantly higher in obesity-simulation scenarios (both p < 0.001). No significant differences were observed between the two obesity-simulation conditions (difference 0.61 mm, 95% CI -1.25 to 2.47; p = 0.523), indicating that elevation of the paramedic did not improve CPR performance. CONCLUSIONS: Simulated obesity markedly impairs chest compression quality despite increased paramedics' effort, likely due to biomechanical constraints. The 10 cm elevation of the paramedic did not improve compression effectiveness. These findings highlight the need for targeted strategies and further prospective clinical studies to optimize CPR in patients with obesity.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Relationship Between Body Mass Index and Chest Compression Quality Following Standardized Basic Life Support Training in Nurses: A Prospective Simulation Study.Healthcare (Basel, Switzerland) · 2026
- "Resuscitation on the go"- Musculoskeletal discomfort, CPR quality and provider experiences in a transit ambulance setting: A simulated, mixed-methods study.International journal of emergency medicine · 2026
- Thoracoabdominal pressure transmission during prone and supine cardiopulmonary resuscitation in fresh-frozen human cadaversbioRxiv · 2026
- ECPR for cardiac arrest caused by postoperative massive pulmonary embolism in a super-morbidly obese patient: A case reportClinical Critical Care · 2026
- Mechanical Versus Manual CPR as Performed in a Complex Ski Patrol Environment: A Prospective, Crossover Study.Wilderness & environmental medicine · 2026
- Hypoxemia caused by a body-positioning device during endoscopic retrograde cholangiopancreatography in a patient with severe obesity.Clinical journal of gastroenterology · 2026