Electrochemical Lateral Flow Assays: Signal-Generation Mechanisms, Material Architectures, and Translational Pathways for Quantitative Point-of-Care Diagnostics.
Thangapandi Kalyani
School of Medical Science and Technology, Indian Institute of Technology, Kharagpur, India.
Key points
From the paper's conclusion- This review examines electrochemical lateral flow assays (eLFAs) through a design-oriented framework that connects signal-generation mechanisms, electrode materials, device architecture, and translational feasibility.
Abstract
Lateral flow assays (LFAs) are widely used point-of-care diagnostic platforms because they are simple, rapid, low-cost, and easy to operate. The integration of electrochemical transduction into lateral flow platforms enables biorecognition events to be converted into measurable electrical signals. This approach supports portable, digitally readable, and user-friendly diagnostic testing. This review examines electrochemical lateral flow assays (eLFAs) through a design-oriented framework that connects signal-generation mechanisms, electrode materials, device architecture, and translational feasibility. It first discusses why traditional LFAs are constrained by optical readout and then summarizes the major electrochemical modes used in eLFAs, including amperometric, voltammetric, and impedimetric approaches. The principal signal-transduction strategies are then analyzed, including enzyme-mediated amplification, redox-active probes, metallic nanoparticle dissolution, direct electroactive labels, and label-free interfacial sensing. Particular emphasis is placed on how these mechanisms interact with material choice and physical integration strategy, including external electrodes, ex situ measurement formats, and fully integrated on-strip transducers. By comparing these approaches, this review highlights the tradeoffs between sensitivity, simplicity, manufacturability, and user operation. Finally, the major translational barriers that continue to limit real-world implementation are discussed, including reproducibility, biofouling, flow control, user-friendliness, regulatory validation, large-scale manufacturing, and sustainability.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Transport-Reaction-Signal Coupling in Lateral Flow Assays for Next-Generation Point-of-Care Diagnostics.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026
- From Bench to Bedside: Translating Electrochemiluminescence Diagnostics to Point-of-Care Applications.Chemical & biomedical imaging · 2026
- Trends of nucleic acid – based point-of-care diagnostics for infectious diseasesJournal of Biological Engineering · 2026
- Smartphone-connected, battery-free aptamer-based digital test for quantification of procalcitonin and monitoring of infection at the point of caremedRxiv · 2026
- Multiscale Strategies for Advancing Reader-Free Colourimetric Point-of-Care (POCT) DiagnosticsACS Applied Engineering Materials · 2026
- Origami-Paper Microfluidics for Point-of-Need Analysis.Analytical chemistry · 2026