Computer methods in biomechanics and biomedical engineering

Mechanical competence of proximal tibia in persons with spinal cord injury: development of a computational framework to quantify torsional and compressive stiffness and strength.

William Kuo, Christopher M Cirnigliaro, Anmol Doss, Noam Y Harel, Christopher P Cardozo, Steven Kirshblum, William A Bauman, Saikat Pal

Department of Biomedical Engineering, New Jersey Institute of Technology, Newark, New Jersey, USA. · Spinal Cord Damage Research Center, James J. Peters Veterans Affairs Medical Center, Bronx, New York, USA.

Key points

From the paper's conclusion
  • We created subject-specific finite element models of 53 proximal tibias (22 SCI, 5 AB) and quantified two torsional (stiffness, Kt and ultimate strength, Tult) and two compressive (stiffness, Kc and ultimate strength, Cult) metrics.

Abstract

This study developed a framework to quantify the mechanical competence of the proximal tibia in spinal cord injury (SCI) and able-bodied (AB) participants. We created subject-specific finite element models of 53 proximal tibias (22 SCI, 5 AB) and quantified two torsional (stiffness, Kt and ultimate strength, Tult) and two compressive (stiffness, Kc and ultimate strength, Cult) metrics. We report the distributions of Kt, Tult, Kc, and Cult, and a minimum number of metrics required to quantify the mechanical competence of the proximal tibia. This work provides a foundation for confidence interval-based thresholds to predict fracture risk in persons with SCI.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers