Assessing functional capacity in patients with chronic low back pain: validity and reliability of the Glittre-ADL test.
Merve Firat, Basak Kavalci-Kol, Figen Tuncay
Department of Physical Therapy and Rehabilitation, Kırşehir Ahi Evran University, Kırşehir, Türkiye. · Pilot University Health Coordinatorship, Geothermal Resource Rehabilitation Application and Research Center, Kırşehir Ahi Evran University, Kırşehir, Türkiye.
Key points
From the paper's conclusion- As an objective, performance-based measure, the Glittre-ADL test demonstrated evidence of test-retest reliability and construct validity for assessing ADL-related functional limitations in individuals with CLBP. However, completion time was systematically shorter at the second assessment, suggesting a possible learning or familiarization effect; therefore, changes observed across repeated Glittre-ADL assessments should be interpreted cautiously.
Abstract
BACKGROUND: While chronic low back pain (CLBP) impairs individuals' capacity to perform activities of daily living (ADL), objective, performance-based assessments of functional capacity in this patient population remain limited. PURPOSE: This study aimed to investigate the test-retest reliability and construct validity of the Glittre-ADL test as an assessment tool for ADL and functional capacity in individuals with CLBP. METHODS: This cross-sectional study involved 42 participants (28 female, 14 male), with a median age of 42.50 years (Q1-Q3: 24.50-54.25). The Glittre-ADL test was used to evaluate ADL performance. Construct validity was examined by correlating Glittre-ADL performance with comparator measures assessing related domains, including functional exercise capacity using the 6-minute walk test (6MWT), lower extremity endurance using the 1-minute sit-to-stand test (1STS), functional mobility using the timed up and go (TUG) test, and self-reported disability using the Oswestry Disability Index (ODI). Test-retest reliability was evaluated by repeating the Glittre-ADL test after a one-week interval. The intraclass correlation coefficient [ICC(A,1)], standard error of measurement (SEM), and minimal detectable change at the 95% confidence level (MDC95) were subsequently calculated. RESULTS: The ICC(A,1) for repeated Glittre-ADL measurements was 0.776 (95% CI: 0.389-0.903), with an SEM of 0.40 min and an MDC95 of 1.12 min. Strong correlations were observed between the first Glittre-ADL test result and 6MWT distance (r = -0.789, p < .001) and TUG time (r = 0.797, p < .001). Moderate correlations were observed with 1STS repetitions (r = -0.531, p < .001) and ODI score (r = 0.542, p < .001), supporting its construct validity. CONCLUSION: As an objective, performance-based measure, the Glittre-ADL test demonstrated evidence of test-retest reliability and construct validity for assessing ADL-related functional limitations in individuals with CLBP. However, completion time was systematically shorter at the second assessment, suggesting a possible learning or familiarization effect; therefore, changes observed across repeated Glittre-ADL assessments should be interpreted cautiously.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Proposal and Initial Validation of a Brief Questionnaire for Epidemiological Assessment of Low Back Pain.Pain research & management · 2026
- Performance-based functional assessment in ankylosing spondylitis: Clinical utility and validation of the Back Performance Scale (BPS-TR).Journal of back and musculoskeletal rehabilitation · 2026
- Convergent validity of the position-reposition and thoracolumbar dissociation tests in patients with recurrent low back pain in remission.Brazilian journal of physical therapy · 2026
- Lumbar mobility and strength correlate with low back pain and quality of life.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2026
- Test-retest reliability and validity of the 1-minute sit-to-stand test in patients with burn injury: An alternative to the 6-minute walk test for post-acute recovery.Burns : journal of the International Society for Burn Injuries · 2026
- Reliability and feasibility of the ankylosing spondylitis performance index (ASPI) in routine clinical care for patients with axial spondyloarthritis.Clinical rheumatology · 2026