Clinical rheumatology

Reliability and feasibility of the ankylosing spondylitis performance index (ASPI) in routine clinical care for patients with axial spondyloarthritis.

Pasoon Hellamand, Marleen G H van de Sande, Irene E van der Horst Bruinsma, Salima F E van Weely

Department of Clinical Immunology and Rheumatology, Free University Amsterdam, Amsterdam UMC, Amsterdam, Netherlands. p.hellamand@amsterdamumc.nl. · Amsterdam Rheumatology Immunology Center (ARC), Amsterdam, Netherlands.

Observational · n=39

Key points

From the paper's conclusion
  • This study supports the ASPI as a reliable, feasible, and acceptable instrument for evaluating physical function in patients with axSpA. Together with previous evidence on its clinimetric properties, these findings support its potential use as a complementary performance-based measure alongside patient-reported outcomes. Larger studies are needed to evaluate its broader implementation across diverse clinical settings. Key Points • Although the ASPI has demonstrated validity, reliability, and responsiveness in research settings, evidence on its feasibility and reliability in routine clinical care has been limited. • The ASPI showed excellent test-retest reliability in routine care, with intraclass correlation coefficients meeting the threshold for individual-level assessment. • The ASPI was feasible and acceptable from the patient perspective, with high completion rates, clear instructions, and favorable ratings for annual administration. • Together with previous evidence on its clinimetric properties, these findings strengthen the rationale for using the ASPI as a complementary performance-based measure of physical function in routine axSpA care, while larger studies are needed to evaluate its implementation across diverse clinical settings.

Abstract

OBJECTIVE: Patients with axial spondyloarthritis (axSpA) frequently experience limitations in physical function. The performance-based ankylosing spondylitis performance index (ASPI), developed from BASFI items, has demonstrated validity, reliability, and responsiveness in research settings for evaluating physical function. We aimed to assess its reliability and feasibility in routine care. METHODS: In this prospective observational cohort study, patients with axSpA aged 18-70 years were included if they had a clinical diagnosis of axSpA and were either on a stable NSAID dose for >6 weeks, a stable tumor necrosis factor inhibitor (TNFi) dose for >3 months, or had axSpA without sacroiliitis on X-ray initiating TNFi. ASPI was performed at baseline and 3 months. Test-retest reliability at baseline and 3 months was assessed in the stable treatment group. Feasibility was assessed in all patients using patient-reported outcomes. RESULTS: A total of 39 patients (32 on stable treatment) were included, with a mean age of 44 years, and ~50% women. Bland-Altman analysis revealed low systematic bias (0.1 s), with limits of agreement from -4.4 to 4.6 s. The ASPI composite score showed excellent reliability (ICCs 0.90-0.91). Feasibility was high with a 92% completion rate at baseline; median (IQR) perceived burden score of 5 (2-7) (0 = no burden, 10 = burdensome); and a median score of 10 (1 = unfavorable, 10 = favorable) for annual administration. CONCLUSION: This study supports the ASPI as a reliable, feasible, and acceptable instrument for evaluating physical function in patients with axSpA. Together with previous evidence on its clinimetric properties, these findings support its potential use as a complementary performance-based measure alongside patient-reported outcomes. Larger studies are needed to evaluate its broader implementation across diverse clinical settings. Key Points • Although the ASPI has demonstrated validity, reliability, and responsiveness in research settings, evidence on its feasibility and reliability in routine clinical care has been limited. • The ASPI showed excellent test-retest reliability in routine care, with intraclass correlation coefficients meeting the threshold for individual-level assessment. • The ASPI was feasible and acceptable from the patient perspective, with high completion rates, clear instructions, and favorable ratings for annual administration. • Together with previous evidence on its clinimetric properties, these findings strengthen the rationale for using the ASPI as a complementary performance-based measure of physical function in routine axSpA care, while larger studies are needed to evaluate its implementation across diverse clinical settings.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers