Key points
From the paper's conclusion- The short-term stability was investigated using the FD-FT-ICR technique, resulting in a minimum relative magnetic-field variation of δB/B ≃ 5 × 10-8 for averaging times between 30 and 60 s.
Abstract
In this work, we investigate the magnetic-field stability of a Penning trap operated with a cryogen-free superconducting magnet through cyclotron-frequency measurements of a single laser-cooled calcium ion using two complementary photon-based detection techniques: a pulsed optical method for determining the three ion eigenfrequencies and Fluorescence-Detected Fourier-Transform Ion-Cyclotron-Resonance (FD-FT-ICR). For the former technique, the data-analysis procedure was revisited, considering it as the dominant contribution to the measurement uncertainty and yielding a long-term magnetic-field drift (1/B)(dB/dt) = -3.07(32) × 10-9 h-1. This value is comparable with those reported for high-precision Penning-trap experiments employing liquid-helium-based superconducting magnets. The short-term stability was investigated using the FD-FT-ICR technique, resulting in a minimum relative magnetic-field variation of δB/B ≃ 5 × 10-8 for averaging times between 30 and 60 s. Furthermore, this technique enables direct cyclotron-frequency determinations on timescales as short as a few seconds, providing access to magnetic-field fluctuations that are generally not resolved in conventional Penning-trap experiments.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Sub-Doppler cooling of bosonic strontium in a two-color magneto-optical trapPhysical Review A · 2026
- Determination of factors that allow cryogenic nanoscopy with high power illumination without devitrificationPLoS ONE · 2026
- Low Vibration Closed-Cycle Flow Cryostat for Ion-Cavity ExperimentsarXiv · 2026
- Liquid-Nitrogen-Cooled ^{40}Ca^{+} Ion Optical Clock with a Systematic Uncertainty of 4.4×10^{-19}.Physical review letters · 2026
- Suppressing cavity frequency noise using a Kerr nonlinearityApplied Physics Letters · 2026
- All-optical low-field magnetometry of superconductors using NV nanodiamondsMeasurement · 2026