Impact of instrumental effects and target thickness on the SPARC magnetic proton recoil spectrometer response function.
M Dalla Rosa, D Rigamonti, S Mackie, M Nocente, B I Buschmann, J Carmichael, J Kunimune, S Fugazza,
Department of Physics, University of Milano-Bicocca, Milan 20126, Italy. · Institute for Plasma Science and Technology, National Research Council, Milan 20125, Italy.
Key points
From the paper's conclusion- The hodoscope is divided into three regions with different channel widths, depths, and lengths, jointly optimized to satisfy three coupled physical requirements: sufficient energy resolution at the 14.1 MeV DT peak, full proton containment up to 18.75 MeV, and limitation of the background through minimization of the detector volume.
Abstract
The SPARC tokamak aims to demonstrate net fusion power gain in tokamaks (Q-fus > 1). To measure neutron emission, a neutron spectrometer based on the magnetic proton recoil technique is being developed. This diagnostic operates by converting collimated neutrons into recoil protons through elastic scattering on a polyethylene target. The recoiled protons are then separated based on their momentum by a magnetic field and subsequently detected by a hodoscope composed of plastic scintillation detectors coupled to photomultiplier tubes. This allows neutron energies in the 2-20 MeV range to be discriminated, though only neutrons in a narrower energy window (±25% around the selected central energy) can be measured. The instrument will contribute to the determination of the total fusion power and provide information on plasma parameters such as ion temperature and the presence of non-thermal fuel ions. In this study, the design rationale of the hodoscope is presented and the main instrumental effects that govern proton collection are characterized. The hodoscope is divided into three regions with different channel widths, depths, and lengths, jointly optimized to satisfy three coupled physical requirements: sufficient energy resolution at the 14.1 MeV DT peak, full proton containment up to 18.75 MeV, and limitation of the background through minimization of the detector volume. Three correction factors are evaluated through dedicated simulations: the vertical signal loss due to protons falling outside the scintillator rod length, the cross-talk between adjacent channels, and the background contribution per channel. A correction scheme combining all three factors is presented.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Design and characterization of the magnetic proton recoil neutron spectrometer for burning plasma studies on SPARC (invited).The Review of scientific instruments · 2026
- The next-generation magnetic recoil spectrometer for measurements of the absolute neutron spectrum at Pacific Fusion's demonstration system.The Review of scientific instruments · 2026
- A compact recoil spectrometer for time integrated neutron energy spectrum measurements on the Z machine (invited).The Review of scientific instruments · 2026
- Conceptual design of the electron-optics of the magnetic electron recoil gamma-ray spectrometer.The Review of scientific instruments · 2026
- A forward model for the design of a constant-time-resolution proton recoil telescope.The Review of scientific instruments · 2026
- Gamma-electron conversion on MERGS (magnetic electron recoil gamma-ray spectrometers) for fusion diagnostics.The Review of scientific instruments · 2026