Nanosecond-resolved 266 nm Mach-Zehnder interferometry of laser-produced dense plasmas generated in supercritical helium.
Kyusang Cho, Juho Lee, Gunsu Yun
Department of Physics, POSTECH, 77 Cheongam-ro, Nam-gu, Pohang 37673, Republic of Korea.
Key points
From the paper's conclusion- We developed a nanosecond-resolved 266 nm Mach-Zehnder interferometer for dense laser-produced plasmas generated in supercritical helium at 100 bar.
Abstract
We developed a nanosecond-resolved 266 nm Mach-Zehnder interferometer for dense laser-produced plasmas generated in supercritical helium at 100 bar. A 1064 nm pump was focused into the helium, and the induced phase shift of a 266 nm probe was recorded with a 3 ns intensified charge-coupled device gate. Separately acquired plasma-arm-only and reference-arm-only images were used to normalize each interferogram before two-dimensional Fourier phase retrieval. Owing to the inherent limitations of single-wavelength interferometry, which cannot distinguish between free-electron and neutral-species contributions, the measured phase shift is reported as an electron-density-equivalent quantity using an electron-only conversion. At 10 ns, the maximum line-of-sight-integrated value in the averaged frame was 2.01 × 1017 cm-2, whereas the median from 19 fringe-recoverable frames was 2.22 × 1017 cm-2. A regularized finite-shell Abel inversion was applied to the 10 ns averaged profile. Varying the emission-defined outer-radius criterion from 10% to 50% produced on-axis electron-density-equivalent values of 2.04-2.42 × 1018 cm-3, quantifying the Abel-inverted on-axis sensitivity to the boundary definition. Adopting the 30% criterion as the nominal boundary gave (2.31 ± 0.16) × 1018 cm-3 from phase-noise uncertainty, excluding unresolved systematic effects. Normalized visibility, Fourier-sideband signal-to-noise ratio, phase noise, and region of interest quantify the region over which phase retrieval remains well conditioned. Electron-ion free-free absorption and finite-collision-frequency effects are estimated, whereas probe refraction remains an unresolved systematic uncertainty. Our UV interferometer demonstrates the integrated implementation and quantitative characterization of the diagnostic in 100 bar supercritical helium, while defining the limits of its absolute-density interpretation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Generalized theory of second-harmonic orthogonally polarized dispersion interferometry and implementation for pulsed power electrode plasma measurements.The Review of scientific instruments · 2026
- Design of a collective Thomson scattering system for diagnosing mid-infrared laser-produced plasmas for extreme ultraviolet source.The Review of scientific instruments · 2026
- On the application of laser interferometry to measure the density of a high-Mach-number hypersonic plasma jetPhysics of Plasmas · 2026
- Optical cavity-based measurements of electron density in a non-equilibrium atmospheric-pressure plasmaPhysics of Plasmas · 2026
- Integrated frequency-modulated continuous-wave (FMCW) interferometer with in situ common-path referencing for plasma diagnostics using a commercial radar system-on-chip.The Review of scientific instruments · 2026
- X-ray transmission measurements of high-temperature Al plasma by using Z-pinch dynamic hohlraum on 10-MA facilityPlasma Physics and Controlled Fusion · 2026