Integrated frequency-modulated continuous-wave (FMCW) interferometer with in situ common-path referencing for plasma diagnostics using a commercial radar system-on-chip.
Jinuo Yu, Jinlin Xie, RuoXuan Guo, Jinchen Yang, Yiduo Xu, Ge Zhuang
Department of Plasma Physics and Fusion Engineering, School of Nuclear Science and Technology, University of Science and Technology of China, 96 Jinzhai Road, Hefei, China. · Binhu Campus, Hefei No. 1 High School, Hefei, Anhui, China.
Key points
From the paper's conclusion- Here, we report an integrated frequency-modulated continuous-wave interferometer for plasma diagnostics using a commercial 60-64 GHz radar system-on-chip and, critically, an in situ common-path reference architecture that enables phase-stable operation with industrial hardware.
Abstract
Millimeter-wave interferometry is a standard diagnostic for line-integrated electron density, but conventional implementations typically rely on discrete high-frequency sources, mixers, and separately aligned reference paths. Here, we report an integrated frequency-modulated continuous-wave interferometer for plasma diagnostics using a commercial 60-64 GHz radar system-on-chip and, critically, an in situ common-path reference architecture that enables phase-stable operation with industrial hardware. The key design feature is the intentional use of aperture-clipping reflection from the diagnostic-window flange as a stationary reference echo, while the transmitted beam core traverses the plasma and is reflected by a mirror. Because the reference and measurement echoes are generated by the same chirp and share the same transceiver, launch optics, and diagnostic port, differential phase extraction suppresses common-mode oscillator drift, thermal drift, and mechanical vibration without a separate reference arm. A high-duty-cycle chirp configuration and chirp-by-chirp FFT phase retrieval provide a temporal resolution of 120 μs. Experiments on the Keda Linear Magnetized Plasma device show that the common-path-referenced scheme reduces the phase standard deviation from 0.34° to 0.17° and suppresses the dominant 22 Hz vibration component by more than 12 dB, yielding a minimum detectable line-integrated density of 2 × 1014 m-2. These results demonstrate a compact and scalable interferometer architecture for plasma diagnostics based on commercially integrated millimeter-wave hardware.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A fiber-coupled heterodyne laser interferometer for plasma density measurements.The Review of scientific instruments · 2026
- Nanosecond-resolved 266 nm Mach-Zehnder interferometry of laser-produced dense plasmas generated in supercritical helium.The Review of scientific instruments · 2026
- Generalized theory of second-harmonic orthogonally polarized dispersion interferometry and implementation for pulsed power electrode plasma measurements.The Review of scientific instruments · 2026
- Large-range nanoradian-level tilt sensing using an unequal-arm dual-beam interferometer with deep frequency modulation readout.Applied optics · 2026
- Absolute measuring interferometric high-speed profilometer using wavelength modulation at ultrasonic frequenciesMeasurement Science and Technology · 2026
- FM and double modulation interferometry with sub-nanometer resolution using the iLens techniqueApplied Physics Letters · 2026