First results from the time resolved opacity spectrometer on the National Ignition Facility (invited).

Y P Opachich, P M Kozlowski, P A Bradley, J G Buscho, A C Carpenter, P B Cho, J W Corbin, E C Dutra,

Lawrence Livermore National Laboratory, Livermore, California 94550, USA. · Los Alamos National Laboratory, Los Alamos, New Mexico 87545, USA.

Computational

Key points

From the paper's conclusion
  • The first results from OpSpecTR presented herein demonstrate significantly improved fidelity in opacity measurements under high-temperature conditions, advancing experimental constraints on stellar opacity models.

Abstract

Radiative opacity plays a central role in determining stellar structure, with iron contributing significantly to the solar opacity, particularly near the radiation-convection boundary. Current atomic models of opacity remain a major source of uncertainty, factoring into discrepancies between standard solar models and helioseismic observations. Agreement with models could be attained if key opacity values were 10%-50% larger, motivating high-precision experimental benchmarks at stellar interior conditions. The Opacity-on-National Ignition Facility campaign measures iron opacity via x-ray transmission through samples heated in a hohlraum. Previous measurements using the time-integrated opacity spectrometer (OpSpec) have been limited to temperatures <160 eV and electron densities ∼1021-1022 cm-3. Higher temperatures are achievable, but measurements were precluded by strong background emission. To address this limitation, a new time-resolved spectrometer, OpSpecTR, was developed. OpSpecTR employs an elliptically bent crystal and a grazing-incidence x-ray mirror to achieve high spectral purity, and a small crossover slit to minimize background. Time-resolved spectra in the 1-2 keV range are recorded on three ns-gated hCMOS detectors, simultaneously measuring transmitted, backlighter, and self-emission signals required for opacity extraction. Nanosecond-scale gating isolates the backlighter pulse and reduces background contributions by up to 70%. Spectral resolving power is also improved ∼2× relative to the time-integrated instrument. The first results from OpSpecTR presented herein demonstrate significantly improved fidelity in opacity measurements under high-temperature conditions, advancing experimental constraints on stellar opacity models.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

First results from the time resolved opacity spectrometer on the National Ignition Facility (invited) — Science Skim