First results from the time resolved opacity spectrometer on the National Ignition Facility (invited).
Y P Opachich, P M Kozlowski, P A Bradley, J G Buscho, A C Carpenter, P B Cho, J W Corbin, E C Dutra,
Lawrence Livermore National Laboratory, Livermore, California 94550, USA. · Los Alamos National Laboratory, Los Alamos, New Mexico 87545, USA.
Key points
From the paper's conclusion- The first results from OpSpecTR presented herein demonstrate significantly improved fidelity in opacity measurements under high-temperature conditions, advancing experimental constraints on stellar opacity models.
Abstract
Radiative opacity plays a central role in determining stellar structure, with iron contributing significantly to the solar opacity, particularly near the radiation-convection boundary. Current atomic models of opacity remain a major source of uncertainty, factoring into discrepancies between standard solar models and helioseismic observations. Agreement with models could be attained if key opacity values were 10%-50% larger, motivating high-precision experimental benchmarks at stellar interior conditions. The Opacity-on-National Ignition Facility campaign measures iron opacity via x-ray transmission through samples heated in a hohlraum. Previous measurements using the time-integrated opacity spectrometer (OpSpec) have been limited to temperatures <160 eV and electron densities ∼1021-1022 cm-3. Higher temperatures are achievable, but measurements were precluded by strong background emission. To address this limitation, a new time-resolved spectrometer, OpSpecTR, was developed. OpSpecTR employs an elliptically bent crystal and a grazing-incidence x-ray mirror to achieve high spectral purity, and a small crossover slit to minimize background. Time-resolved spectra in the 1-2 keV range are recorded on three ns-gated hCMOS detectors, simultaneously measuring transmitted, backlighter, and self-emission signals required for opacity extraction. Nanosecond-scale gating isolates the backlighter pulse and reduces background contributions by up to 70%. Spectral resolving power is also improved ∼2× relative to the time-integrated instrument. The first results from OpSpecTR presented herein demonstrate significantly improved fidelity in opacity measurements under high-temperature conditions, advancing experimental constraints on stellar opacity models.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- AlMg transmission measurements on the National Ignition Facility with novel uncertainty quantification method for point-projection geometryPhysics of Plasmas · 2026
- Expanded higher energy channel for the National Ignition Facility's soft x-ray opacity spectrometer (OpSpec).The Review of scientific instruments · 2026
- The OMEGA-extended performance streaked optical pyrometer with spectral resolution.The Review of scientific instruments · 2026
- Design and characterization of a hohlraum for dynamic radiography at the OMEGA EP (extended performance) laser system.The Review of scientific instruments · 2026
- A physics-based simulation framework for resolving ignition-scale hohlraum drive discrepanciesPhysics of Plasmas · 2026
- Demonstration of ignition-driven radiation transport through a THOR hohlraum.Physical review. E · 2026