Physics of Fluids

Influence of cough on mucus film breakup and droplet formation in a model human airway

Sudipta Saha, S. K. Hasan Raja, Aranyak Chakravarty, Sourav Sarkar

Key points

From the paper's conclusion
  • In contrast, PVT exhibits a comparatively weaker and non-monotonic influence on film fragmentation—the breakup time increases linearly with PVT, while the breakup length varies non-monotonically along with similar variations in droplet counts, mean size, and residual film thickness.

Abstract

Air–mucus interaction during respiratory events is important for understanding mucus transport and assessing bio-aerosol (droplet) formation. In the present study, the interfacial dynamics of air–mucus interaction within a simplified airway geometry are numerically investigated considering transient, cough airflow. A volume-of-fluid-based multiphase flow framework is employed to examine how transient cough parameters, viz., cough peak flow rate (CPFR) and peak velocity time (PVT), fundamentally influence the underlying mechanism governing mucus film instability and subsequent film fragmentation. This has not been investigated before. Results show that the fundamental governing mechanism of mucus film instability remains qualitatively similar, irrespective of the airflow nature. Steady airflow is observed to predominantly produce droplets through ligament-mediated breakup, resulting in fewer and larger droplets. Stronger shear stress during a transient cough causes enhanced film rupture, thereby promoting fragmentation. Maximum shear stress increases by 21.7% when transitioning from steady airflow to mild cough, accompanied by a 19.2% decrease in mean droplet size and a 167% increase in droplet count. Increasing CPFR (Wea,peak) is observed to enhance film breakup—a shorter breakup time, larger breakup length, increased droplet count, reduced mean size of the droplets, and smaller residual film thickness are observed. In contrast, PVT exhibits a comparatively weaker and non-monotonic influence on film fragmentation—the breakup time increases linearly with PVT, while the breakup length varies non-monotonically along with similar variations in droplet counts, mean size, and residual film thickness. These findings highlight the critical role played by transient airflow in governing mucus film breakup during coughs.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Influence of cough on mucus film breakup and droplet formation in a model human airway — Science Skim