Spatially controlled x-ray field generation by a twin cylindrical x-ray gun.
S Szatmári
Institute of Physics, University of Szeged, Dóm tér 9, H-6720 Szeged, Hungary.
Key points
From the paper's conclusion- Based on the r-1 spatial dependence of the radiation, this configuration offers a more than twofold increase in the intensity of the x-ray field, alongside improved spatial homogeneity, while maintaining the previously reported spatial tunability of the preionization.
Abstract
Homogeneous excitation of large-aperture excimer gain modules by discharge pumping involves a critical interplay between the temporal and spatial properties of both pumping and preionization. Previously, a promising x-ray preionization scheme based on the use of two cylindrical x-ray guns was introduced, where the spatial distribution of the generated x-ray field could be effectively controlled by their positions. It has not been exploited yet that the rotation of the guns offers one more free parameter to fine-tune the spatial properties of the x-ray field due to the angular dependence of their emission. In this paper, we demonstrate both numerically and experimentally that by utilizing the specific angular dependence of the emission from cylindrical, cold-cathode x-ray guns, an improved spatial homogeneity of the generated x-ray field can be achieved. Through a proper choice of gun positions and cathode orientation, the spatial boundaries of the generated x-ray field for a given homogeneity can be significantly extended. This allows for a decreased distance between the x-ray guns and the volume to be homogeneously irradiated, where the minimum useable distance is no longer limited by the increased inhomogeneity of the field but only by practical geometrical limitations. Based on the r-1 spatial dependence of the radiation, this configuration offers a more than twofold increase in the intensity of the x-ray field, alongside improved spatial homogeneity, while maintaining the previously reported spatial tunability of the preionization. These optimized arrangements can be deployed in closer proximity to-or even inside-the discharge chamber.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Research on ultra-fast fabrication method of bidirectionally anisotropic Ion beam figuring for large-aperture nanoradian X-ray mirrors.Optics express · 2026
- Design of an Integrated Large-Angle Open-Ring Device for In Situ X-Ray Imaging Inspection of Ultra/Extra High-Voltage Gas-Insulated Metal-Enclosed Transmission LinesEng · 2026
- Detective quantum efficiency (DQE)-oriented design of a transparent scintillator tandem x-ray/optical microscope for photon-starved 7.2-keV radiography at the National Ignition Facility (NIF).The Review of scientific instruments · 2026
- Characterization and optimization of a laser-produced x-ray source for x-ray radiography.The Review of scientific instruments · 2026
- Controlling X-ray emission with dispersion-engineered surface plasmon polaritonsOptics Letters · 2026
- Multimode objective lens for momentum microscopy and x-ray photoemission electron microscopy: ExperimentsReview of Scientific Instruments · 2026