Electrode erosion and lifetime of field-distortion spark gap switches under 88-kA repetitive discharges.
Xue Wang, Yiheng Zhou, Fengfan Liang, Peng Du, Wuhan Yuan, Y C Francis Thio
Center for Ultimate Energy, ShanghaiTech University, Shanghai 201210, China.
Key points
From the paper's conclusion- This paper systematically investigates the electrode erosion and lifetime characteristics of a three-electrode field-distortion spark gap switch operating at a charging voltage of 4 kV and a peak current of ∼88 kA.
Abstract
This paper systematically investigates the electrode erosion and lifetime characteristics of a three-electrode field-distortion spark gap switch operating at a charging voltage of 4 kV and a peak current of ∼88 kA. Lifetime testing was combined with electrode mass measurements and staged macro- and microscopic characterization to identify the principal degradation processes. The switch exhibits a reproducible non-monotonic delay evolution that correlates with the formation, displacement, and blunting of a cathode surface protrusion. The electrodes exhibit an overall net mass loss, while small early-stage fluctuations may result from material redistribution among the electrodes. Scanning electron microscope observations indicate that repetitive localized thermal shock is the fundamental driving force for crack initiation. Spatially nonuniform energy deposition, governed by arc-root attachment and plasma/gas dynamics, produces distinct pit morphologies and thermal-stress distributions. Type II pits tend to aggregate at crack sites and play an increasingly important role in subsequent discharges. The more severe fragmentation on the anode-facing side of the trigger electrode is attributed to greater inferred plasma exposure and energy deposition, which promote type II pit formation, intergranular crack-network development, and eventual fragment detachment. These results provide insight into electrode material selection and lifetime optimization for high-current spark gap switches.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Effect of Current on the Characteristics of Splashed Particles from AgSnO 2 Contacts in a 270 V DC ArcPhysica Scripta · 2026
- From Thermal Ablation to Mechanical Fracture: Lightning-Caused Breakage of Insulated Conductors Under Thermal–Mechanical Coupling of Power-Frequency Follow Current ArcsEng · 2026
- Research on the double-sided surface flashover characteristics of the irregular ceramic insulator in high-power electron gunsJournal of Applied Physics · 2025
- Arc Dynamics and Material Erosion of Pantograph-Catenary Contacts Under a Rotating Permanent-Magnet Field.Materials (Basel, Switzerland) · 2026
- Impacts of nozzle ablation on arc dynamic performance under excessively high short-circuit current interruptionPhysica Scripta · 2026
- Effect of Breaking Speed on Plasma Distribution Characteristics During the Arc Extinction ProcessEngineering Research Express · 2026