科研速览 · Science Skim继续刷下去 · Keep skimming →
◆ New England Journal of Medicine2026-03-29· Medicine

Left Ventricular Unloading in High-Risk Percutaneous Coronary Intervention

D Perera, Matthew Ryan, Saad Ezad, Sohail Q. Khan, Ian Webb, Peter O’Kane, Roshan Weerackody, Matthew Dodd, Matthew Kwok, Lynn Laidlaw, Laura Van Dyck, Benjamin Wrigley, Julian Strange, Alan Bagnall, Farzin Fath-Ordoubadi, Vasileios F. Panoulas, Andrew Ladwiniec, John R. Davies, Alexander Chase, Colum Owens, Stuart Watkins, Haseeb Rahman, Nilesh Pareek, Krishnaraj Rathod, John Rawlins, Richard Evans, SP Hoole, Rod Stables, Nick Curzen, Tim Clayton

原始摘要(英文原文)· Original abstract
BACKGROUND: Complex percutaneous coronary intervention (PCI) in patients with severely impaired left ventricular function carries a high risk of death and complications. Whether percutaneous left ventricular unloading improves outcomes remains unclear. METHODS: We randomly assigned 300 patients with severe left ventricular dysfunction and extensive coronary artery disease in a 1:1 ratio to a strategy of elective unloading with a microaxial flow pump or to standard care during planned complex PCI. The primary outcome was a hierarchical composite that included death from any cause, disabling stroke, spontaneous myocardial infarction, hospitalization for cardiovascular causes, or periprocedural myocardial injury at a minimum of 12 months, as analyzed according to a win ratio. RESULTS: A total of 148 patients were assigned to receive a microaxial flow pump and 152 to receive standard care. At a median of 22 months (interquartile range, 16 to 30), 36.6% of pairwise comparisons favored the microaxial flow pump, and 43.0% favored standard care (win ratio, 0.85; 95% confidence interval [CI], 0.63 to 1.15; difference, -6.4 percentage points; P = 0.30). Death from any cause occurred in 47 patients in the microaxial-flow-pump group and 33 in the standard-care group (hazard ratio, 1.54; 95% CI, 0.99 to 2.41). There was no material between-group difference in the risk of bleeding or vascular complications. CONCLUSIONS: Among patients with severely impaired left ventricular function undergoing complex PCI, elective left ventricular unloading with a microaxial flow pump did not reduce the risk of major adverse clinical outcomes at a minimum of 12 months. (Funded by the U.K. National Institute for Health and Care Research; CHIP-BCIS3 ClinicalTrials.gov number, NCT05003817.).
读原文 · Read the paper ↗

AI 追问PRO

登录后使用 AI 追问

讨论区

登录后参与讨论

相关论文 · Related

Left Ventricular Unloading in High-Risk Percutaneous Coronary Intervention — 科研速览 Science Skim