Department of Interventional Cardiology, Queen Elizabeth Hospital, University Hospital Birmingham NHS Trust, Birmingham, United Kingdom. Electronic address: dr.elsherif1990@gmail.com. · Department of Interventional Cardiology, Queen Elizabeth Hospital, University Hospital Birmingham NHS Trust, Birmingham, United Kingdom.
Key points
From the paper's conclusion- Microaxial flow pump-assisted PCI was not associated with lower MACE at any time point. MACE at 30 days, almost entirely due to death, was more frequent with pump support, particularly in patients without cardiogenic shock. These observational findings do not support routine prophylactic device use.
Abstract
BACKGROUND: Evidence comparing short- and intermediate-term outcomes after microaxial flow pump-assisted versus standard-care high-risk percutaneous coronary intervention (PCI) is limited. We compared major adverse cardiovascular events (MACE) through 24 months and explored treatment-effect subgroups. METHODS: We conducted a single-centre retrospective propensity score-matched study of 290 patients (145 per group). Propensity scores were estimated using 31 baseline covariates, and 1:1 nearest-neighbour matching without replacement was used to estimate the average treatment effect in treated patients. MACE comprised all-cause mortality, myocardial infarction, or stroke/transient ischaemic attack. Arms were compared using Kaplan-Meier cumulative incidence and absolute risk differences at 30 days, 12 months and 24 months. The cohort included elective cases (20.7%), acute coronary syndromes (79.3%) and pre-procedural cardiogenic shock (20.0%); outcomes were also analysed separately in patients with and without cardiogenic shock. RESULTS: Cumulative MACE incidence with pump support versus standard care was 26.2% versus 17.9% at 30 days (risk difference 8.3%, 95% CI 0.1% to 16.6%), 38.8% versus 30.6% at 12 months (8.3%, -3.1% to 19.4%), and 44.6% versus 39.1% at 24 months (5.4%, -5.7% to 18.0%; log-rank P = 0.206). 63 of the 64 MACE events within 30 days were deaths. The 30-day difference was confined to patients without cardiogenic shock (20.7% versus 6.9%; risk difference 13.8%, 95% CI 5.2% to 22.0%), with no difference in those presenting in shock (48.3% versus 62.1%; -13.8%, -41.4% to 14.3%). CONCLUSIONS: Microaxial flow pump-assisted PCI was not associated with lower MACE at any time point. MACE at 30 days, almost entirely due to death, was more frequent with pump support, particularly in patients without cardiogenic shock. These observational findings do not support routine prophylactic device use.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Outcomes of microaxial flow pump mechanical circulatory support in cardiogenic shockEuropean Heart Journal · 2026
- Left ventricular functional recovery after complex high-risk indicated percutaneous coronary intervention supported with microaxial flow pumpJournal of Cardiovascular Medicine · 2025
- Mechanical Circulatory Support for Complex High-Risk Indicated Percutaneous Coronary Intervention: Network Meta-Analysis of Randomized Trials.Journal of the American Heart Association · 2026
- Bleeding and thrombotic events during micro-axial flow pump support: A European multicenter cohort studyCritical Care · 2026
- Timing of Microaxial Flow Pump Support and In-Hospital Mortality in Infarct-Related Cardiogenic Shock: The TIMING-CS Study.Journal of cardiovascular development and disease · 2026
- Effect of microaxial flow pump on survival in isolated left main infarction related cardiogenic shock. A DanGer Shock substudy analysisEuropean Heart Journal · 2026