Preliminary Results of the Use of a Robotic System in Spine Surgery.

Helton Luiz A Defino, Vinicius Marques Carneiro, Matheus Pippa Defino, Rian Souza Vieira, Thiago Dorigão, Denylson Sanches Fernandes

Department of Orthopedics and Anesthesiology, Faculdade de Medicina de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SPBrazil. · Neurosurgery Division, Department of Surgery and Anatomy, Faculdade de Medicina de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SPBrazil.

Key points

From the paper's conclusion
  • The robotic system demonstrated high accuracy in implant placement and, with increasing experience in its use, was associated with reductions in fluoroscopy time, intraoperative radiation exposure, and the time to record the patient's anatomy.

Abstract

OBJECTIVE: To evaluate the preliminary results of the use of the robotic system in spinal surgery. METHODS: The current prospective study included patients undergoing spinal surgery since the introduction of the robotic system (Mazor X Stealth Edition, Medtronic plc). The study evaluated the time to record the patient's anatomy, the fluoroscopy time, radiation dose, implant insertion time, implant accuracy, and complications. RESULTS: The study assessed 67 patients who received 415 pedicle screws (98 thoracic, 284 lumbar, 1 in a transitional vertebra, and 32 sacral). The time to record the patient's anatomy ranged from 4 to 71 (mean: 16.93 ± 12.49) minutes. The fluoroscopy time ranged from 2.3 to 71.20 (mean: 12.91 ± 11.52) seconds. The amount of radiation administered during the surgical procedure ranged from 0.38 to 12.89 (mean: 3.78 ± 3.29) mGy. The time required for implant insertion into the pedicles ranged from 102 to 323 (mean: 147.90 ± 45.09) seconds. In the axial plane, 95.65% of the implants were types A or B on the Gertzbein-Robbins scale, and, in the sagittal plane, 96.38%. No cases required abandonment of the robotic system. As a complication, one patient developed a neurological deficit. CONCLUSION: The robotic system demonstrated high accuracy in implant placement and, with increasing experience in its use, was associated with reductions in fluoroscopy time, intraoperative radiation exposure, and the time to record the patient's anatomy.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Preliminary Results of the Use of a Robotic System in Spine Surgery — Science Skim