The Figure-of-4 Maneuver: Quantitative Characterization of Lateral Compartment Behavior During Robotic Total Knee Arthroplasty.
Ravi Chandra Vattipalli, Varoon Chand Chand Palakodety
CARE Hospitals, Department of Orthopaedics, Andhra Pradesh, India, Visakhapatnam.
Key points
From the paper's conclusion- Figure-of-4 assessment produced consistently more negative flexion ΔML than conventional assessment (mean difference -2.181 mm; 95% CI -2.414 to -1.947; p < 0.001; Cohen's d = 2.039). Extension ΔML did not differ significantly (mean difference 0.080 mm; 95% CI -0.019 to 0.178; p = 0.113). Preoperative HKA angle did not correlate with the change in flexion ΔML (r = 0.091, p = 0.416) or extension ΔML (r = -0.111, p = 0.318). Conclusion Figure-of-4 assessment consistently demonstrated greater lateral compartment opening in flexion than conventional assessment, while extension measurements remained essentially unchanged. The standardized robotic measurement framework enabled objective quantification of compartment behavior in a positional condition not evaluated during routine assessment. The maneuver characterizes behavior of the prepared knee in a posture associated with common activities of daily living and provides information complementary to conventional assessment.
Abstract
INTRODUCTION: Conventional intraoperative gap assessment is performed in standardized reference positions that do not replicate many functional postures patients assume during daily activities. Physiologic lateral compartment opening becomes most apparent in postures combining flexion, hip external rotation, and relative varus alignment, such as sitting cross-legged, and shoe or sock application. The Figure-of-4 position reproduces this combination intraoperatively. The purpose of this study was to describe the Figure-of-4 maneuver as an intraoperative positional assessment during robotic total knee arthroplasty (rTKA) and quantitatively characterize compartment behavior during its execution using standardized robotic measurements. MATERIALS AND METHODS: Eighty-three consecutive primary rTKAs performed by a single surgeon were retrospectively analyzed. After bone preparation and balancing, with trial components in situ, each knee underwent conventional and Figure-of-4 assessment. The VELYS standardized robotic measurement framework was used for both conditions; only limb posture differed. Compartment behavior was expressed as the medial-to-lateral gap difference (ΔML; medial minus lateral) in flexion and extension. Conventional and Figure-of-4 ΔML were compared within each knee using paired t-tests and Wilcoxon signed-rank tests. Preoperative hip-knee-ankle (HKA) angle was correlated with the change in ΔML using Pearson and Spearman coefficients. RESULTS: Figure-of-4 assessment produced consistently more negative flexion ΔML than conventional assessment (mean difference -2.181 mm; 95% CI -2.414 to -1.947; p < 0.001; Cohen's d = 2.039). Extension ΔML did not differ significantly (mean difference 0.080 mm; 95% CI -0.019 to 0.178; p = 0.113). Preoperative HKA angle did not correlate with the change in flexion ΔML (r = 0.091, p = 0.416) or extension ΔML (r = -0.111, p = 0.318). Conclusion Figure-of-4 assessment consistently demonstrated greater lateral compartment opening in flexion than conventional assessment, while extension measurements remained essentially unchanged. The standardized robotic measurement framework enabled objective quantification of compartment behavior in a positional condition not evaluated during routine assessment. The maneuver characterizes behavior of the prepared knee in a posture associated with common activities of daily living and provides information complementary to conventional assessment.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Intraoperative medial compartment gaps were smaller than lateral compartment gaps across assessed flexion angles during restricted kinematic alignment total knee arthroplasty: a quantitative assessment using an independent tensor.The Knee · 2026
- The anatomical origin of varus predicts the pattern of intraoperative gap imbalance and the correction required to balance the knee in robotic-assisted total knee arthroplasty: a retrospective cohort study.Journal of robotic surgery · 2026
- Agreement and Systematic Differences Between Intraoperative ROSA Hip-Knee-Ankle Measurements and Standing Radiographic Alignment After Robotic-Assisted Total Knee Arthroplasty: A Retrospective Agreement Study.Journal of clinical medicine · 2026
- Planned extension gap widening is associated with greater intraoperative flexion contracture correction in robotic-assisted total knee arthroplasty.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2026
- Greater valgus severity is associated with larger lateral flexion-gap changes between intraoperative assessments during robot-assisted total knee arthroplasty: A retrospective cohort study.Journal of experimental orthopaedics · 2026
- The restricted 4D inverse kinematic alignment workflow: A patient-specific approach integrating both bony and laxity phenotypes for total knee arthroplasty planning.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2026