The Knee

Intraoperative medial compartment gaps were smaller than lateral compartment gaps across assessed flexion angles during restricted kinematic alignment total knee arthroplasty: a quantitative assessment using an independent tensor.

Atsushi Sato, Naoki Okuma, Kanako Izukashi, Marika Mukunoki, Masataka Ota, Jun Oike, Takayuki Okumo, Saki Yagura,

Department of Orthopaedic Surgery, Showa Medical University Fujigaoka Hospital, Yokohama, Kanagawa 227-8501, Japan. Electronic address: atsushi@med.showa-u.ac.jp. · Department of Orthopaedic Surgery, Showa Medical University Fujigaoka Hospital, Yokohama, Kanagawa 227-8501, Japan.

Observational

Key points

From the paper's conclusion
  • In rKA TKA, compartment-specific intraoperative gap behavior under standardized distraction was characterized by medial gaps that changed relatively little and lateral gaps that were consistently larger across the assessed flexion angles. These findings describe the observed intraoperative gap pattern but do not establish ligament strain, postoperative knee kinematics, or clinical stability.

Abstract

PURPOSE: To quantitatively characterize compartment-specific intraoperative gap behavior during restricted kinematic alignment (rKA) total knee arthroplasty (TKA) using an independent medial-lateral tensor. METHODS: Seventy-seven patients (102 knees) who underwent primary rKA TKA were retrospectively analyzed. A restricted kinematic alignment protocol with predefined coronal safety boundaries was applied. After femoral and tibial bone resections, medial and lateral bone gaps were independently measured at 0° and 90° of knee flexion using an independent tensor with a 20-lb torque-driver setting, corresponding to a manufacturer-specified paddle load of 117 N in each compartment. Following femoral trial implantation, implant gaps were measured at 0°, 30°, 60°, 90°, and 120° of flexion. Gap change ratios were calculated relative to the implant gap at full extension. RESULTS: Lateral bone gaps were larger than medial bone gaps in both extension and flexion (compartment effect, p < 0.0001). After placement of the femoral trial component, medial implant gaps changed relatively little across the assessed flexion angles, whereas lateral implant gaps were larger at all assessed flexion angles and increased more markedly, particularly in mid-flexion. Medial gap change ratios ranged from 1.1 to 1.2 across flexion angles, whereas lateral ratios reached approximately 1.2-1.3 in mid-flexion, indicating a greater proportional increase in lateral gap opening. CONCLUSIONS: In rKA TKA, compartment-specific intraoperative gap behavior under standardized distraction was characterized by medial gaps that changed relatively little and lateral gaps that were consistently larger across the assessed flexion angles. These findings describe the observed intraoperative gap pattern but do not establish ligament strain, postoperative knee kinematics, or clinical stability.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers