Journal of cardiothoracic and vascular anesthesia

Discordance Between aPTT and Anti-Xa and Its Association with Hemorrhagic Complications Among ECMO Patients.

Taechawidd Nantawisarakul, Connie Nguyen, Naralys Batista, Andrew Eisenberger, Amy L Dzierba, Sohaila Kakar, Ankur Srivastava, Koji Takeda,

Department of Anesthesiology, Columbia University, New York, NY. · Division of Hematology/Oncology, Department of Medicine, Columbia University Irving Medical Center, New York, NY.

Observational

Key points

From the paper's conclusion
  • Among adult ECMO patients receiving heparin, aPTT > anti-Xa discordance was associated with increased hemorrhage risk. Simultaneous aPTT and anti-Xa assessment may provide clinically meaningful information beyond either assay alone.

Abstract

OBJECTIVES: To determine whether discordance between activated partial thromboplastin time (aPTT) and anti-factor Xa (anti-Xa) is associated with hemorrhage or thrombosis among adults supported with extracorporeal membrane oxygenation (ECMO) and to identify characteristics associated with discordance. DESIGN: Retrospective cohort study. SETTING: High-volume ECMO center. PARTICIPANTS: One hundred thirteen ECMO patients receiving heparin with time-matched aPTT and anti-Xa measurements. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Activated partial thromboplastin time and anti-Xa pairs were classified as concordant or discordant using a linear mixed-effects model with patient-specific random intercepts. Pairs outside the model-derived 95% prediction interval were classified as either aPTT > anti-Xa or aPTT < anti-Xa discordance. Associations between discordance and composite hemorrhagic or thrombotic complications were evaluated using time-varying Cox proportional hazards models. Among 571 paired assays, 94 (16.5%) were discordant. Seventy-seven patients (68.1%) remained concordant, whereas aPTT > anti-Xa discordance developed in 17 (15.0%) and aPTT < anti-Xa discordance developed in 18 (15.9%). Patients with aPTT > anti-Xa discordance had a significantly greater hemorrhage hazard than concordant patients in unadjusted analysis (hazard ratio, 14.85; 95% confidence interval, 3.10-71.05; p = 0.0007). This association was directionally consistent in an exploratory analysis adjusted for international normalized ratio, bilirubin concentration, platelet count, heparin dose, and weight. Hemorrhage was not associated with aPTT < anti-Xa discordance. Neither pattern was associated with thrombosis. Discordance patterns varied by weight, bilirubin concentration, platelet count, heparin dose, and intensive care unit type. CONCLUSIONS: Among adult ECMO patients receiving heparin, aPTT > anti-Xa discordance was associated with increased hemorrhage risk. Simultaneous aPTT and anti-Xa assessment may provide clinically meaningful information beyond either assay alone.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers