Research and practice in thrombosis and haemostasis

Thrombin generation parameters provide independent information on plasma coagulation potential in pediatric patients on extracorporeal membrane oxygenation: a prospective, single-center pilot study.

Dino Mehic, Katie L Clouthier, Nina Buchtele, Adam Miszta, Feng-Chang Lin, Marian A Rollins-Raval, Katherine C Clement, Alisa S Wolberg

Division of Hematology and Hemostaseology, Department of Medicine I, Medical University of Vienna, Vienna, Austria. · Division of Pediatric Critical Care Medicine, Department of Pediatrics, UNC School of Medicine, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, USA.

Observational

Key points

From the paper's conclusion
  • Our data show substantial interindividual and temporal variability in TG parameters. Only TG peak and endogenous thrombin potential correlated with anti-Xa activity. The TG assay may capture plasma coagulation features not reflected by routine assays.

Abstract

BACKGROUND: Extracorporeal membrane oxygenation (ECMO) provides circulatory and respiratory support in pediatric patients with life-threatening organ failure but can alter coagulation. OBJECTIVES: To assess the relationship between a plasma thrombin generation (TG) assay and conventional coagulation assays (activated partial thromboplastin time, antifactor Xa [anti-Xa], and D-dimer) in pediatric ECMO. METHODS: Platelet-poor plasma was collected every 4 hours during the first 48 hours and then daily after ECMO initiation. TG was measured by calibrated automated thrombography. RESULTS: Fifteen ECMO (65% venoarterial and 35% venovenous) patients (median age, 3.3 months; IQR, 0.3-17.5) were included in this prospective, observational pilot cohort study. Median ECMO duration was 7 days (IQR, 5.5-20.5). Seven patients experienced bleeding events, and 5 developed circuit- or cannula-associated thrombosis; of these, 2 experienced both. TG parameters showed substantial interindividual variability. After an initial increase in the median thrombin peak, TG potential declined over the first 48 hours. Neither activated partial thromboplastin time nor D-dimer correlated significantly with TG parameters. Anti-Xa activity correlated significantly with TG peak (r = -0.84; P = .001) and endogenous thrombin potential (r = -0.46; P = .01). At anti-Xa levels ≥ 0.4 IU/mL, TG approached zero, indicating little additional suppression of procoagulant activity at higher anti-Xa levels. CONCLUSION: Our data show substantial interindividual and temporal variability in TG parameters. Only TG peak and endogenous thrombin potential correlated with anti-Xa activity. The TG assay may capture plasma coagulation features not reflected by routine assays.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers