Real-Time Hemodynamic Profiling During Mitral Transcatheter Edge-to-Edge Repair Using Pulse Contour Analysis.

Sandra Uhle, Mathias H Konstandin, Benedikt Alt-Epping, Adrian E Stephan, Benjamin Seybold, Maximilian Dietrich, Florian Uhle, Matthias Eden,

Department of Anesthesiology, Medical Faculty Heidelberg, Heidelberg University, Heidelberg, Germany. Electronic address: mathias.konstandin@med.uni-heidelberg.de. · Department of Cardiology, Medical Faculty Heidelberg, Heidelberg University, Heidelberg, Germany.

Key points

From the paper's conclusion
  • Early hemodynamic changes after M-TEER are not universal but depends on effective MR reduction and ventricular functional reserve. Continuous PCA identified distinct response patterns despite technically successful valve repair.

Abstract

OBJECTIVES: To characterize perioperative hemodynamic response patterns during transcatheter edge-to-edge mitral valve repair (M-TEER) using pulse contour analysis (PCA), and to identify determinants of heterogeneous cardiac output responses following mitral regurgitation (MR) reduction. DESIGN: Prospective, single-center observational study. SETTING: Single tertiary academic medical center. PARTICIPANTS: Sixteen consecutive patients undergoing M-TEER with the PASCAL Ace system (Edwards Lifesciences). INTERVENTIONS: Continuous PCA monitoring was performed from baseline until 4 hours postprocedural alongside periprocedural echocardiography. The primary endpoint was the change in PCA-derived cardiac output (PCA-CO). Secondary endpoints assessed associations between hemodynamic response, procedural success, and ventricular function. MEASUREMENTS AND MAIN RESULTS: Hemodynamic responses varied according to MR reduction and ventricular function. Sustained PCA-CO improvement occurred only with successful MR reduction (≤2+; 24% ± 11%; p = 0.049). Patients with reduced left ventricular ejection fraction showed an early, transient increase in PCA-CO, reaching 108% of baseline (IQR, 86%-136%) after first-device implantation (Dunn-adjusted p = 0.035), which was no longer evident at 4 hours (p = 0.80). In contrast, patients with preserved ejection fraction showed a delayed, sustained increase at 4 hours (14% ± 13%; p = 0.035). Patients with a left ventricular end-diastolic diameter <60 mm also showed increased PCA-CO at 4 hours (12% ± 18%; p = 0.049). Changes in PCA-CO correlated inversely with systolic pulmonary artery pressure (ρ = -0.60; p = 0.026), while left atrial v-wave amplitude decreased significantly (p < 0.001). CONCLUSION: Early hemodynamic changes after M-TEER are not universal but depends on effective MR reduction and ventricular functional reserve. Continuous PCA identified distinct response patterns despite technically successful valve repair.

Read the paper