End-Organ Dysfunction and Postprocedural Perfusion Pressure in Relation to Mortality After Mitral Transcatheter Edge-to-Edge Repair.
Tomofumi Nakatsukasa, Takao Morikawa, Takaaki Sato, Ryo Shigeno, Fumiya Hasegawa, Atsushi Hirohata
Department of Cardiology, The Sakakibara Heart Institute of Okayama, Okayama, Japan.
Key points
From the paper's conclusion- Integrating baseline organ status with procedure-end perfusion identified a high-risk phenotype after M-TEER. Patients with elevated MELD-XI and low PP had the poorest survival. PP did not outperform MAP, indicating a predominantly arterial-pressure signal.
Abstract
BACKGROUND: Outcomes after mitral transcatheter edge-to-edge repair (M-TEER) remain variable despite adequate mitral regurgitation reduction. Baseline end-organ dysfunction and the immediate postprocedural pressure state may capture complementary phases of risk. We assessed long-term mortality by integrating baseline MELD-XI with immediate postprocedural perfusion pressure (PP). AIMS: We aimed to assess the association of baseline MELD-XI and immediate postprocedural perfusion pressure (PP), individually and in combination, with long-term mortality after M-TEER. METHODS: This single-center retrospective study included 238 patients undergoing M-TEER. PP was calculated as mean arterial pressure (MAP) minus central venous pressure (CVP) immediately after the procedure. PP and MELD-XI were analyzed as continuous variables, with prespecified thresholds of PP 60 mmHg and MELD-XI 11 used for grouped risk stratification. RESULTS: During a median follow-up of 730 days, 77 patients died. Lower PP (adjusted hazard ratio [HR] per 10 mm Hg increase, 0.684; 95% confidence interval [CI], 0.572-0.818; p < 0.001) and higher MELD-XI (adjusted HR per 1-point increase, 1.072; 95% CI, 1.014-1.132; p = 0.014) were independently associated with mortality. Compared with high PP/low MELD-XI, risk was highest with low PP/high MELD-XI (adjusted HR, 7.80; 95% CI, 3.78-16.10; p < 0.001) and was also increased with low PP/low MELD-XI (adjusted HR, 2.84; 95% CI, 1.53-5.29; p < 0.001). PP and MAP had similar prognostic performance, whereas CVP was not independently associated with mortality. CONCLUSIONS: Integrating baseline organ status with procedure-end perfusion identified a high-risk phenotype after M-TEER. Patients with elevated MELD-XI and low PP had the poorest survival. PP did not outperform MAP, indicating a predominantly arterial-pressure signal.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- MitraScore: a simple, powerful tool to predict mortality after mitral transcatheter edge-to-edge repairEuropean Heart Journal · 2026
- The predictive value of the hemodynamic profile for survival in patients undergoing transcatheter edge-to-edge mitral valve repair.Acta cardiologica · 2026
- Residual Mitral Regurgitation as a Long-Term Predictor of Mortality After Mitral TEER.JACC. Cardiovascular interventions · 2026
- 6 months follow-up after mitral transcatheter edge-to-edge repair: clinical and procedural determinates that may affect residual mitral regurgitationEuropean Heart Journal · 2026
- Echocardiographic markers of residual pulmonary vascular disease and clinical risk after transcatheter mitral valve edge-to-edge repairEuropean Heart Journal · 2026
- Phenotypes, periprocedural hemodynamic changes, and impact of pulmonary hypertension in patients undergoing mitral transcatheter edge-to-edge repair.Cardiovascular intervention and therapeutics · 2026