Vahid Kiarad, Usman Ahmed, David Liu, Venkatachalam Senthilnathan, Masashi Kai, Louis Chu, Feroze Mahmood, Mehrak Moaddab, Kamal Khabbaz
Reduced tricuspid annular dynamism and increased leaflet tenting are associated with impaired RV-PA coupling. Dynamic 3D TV metrics may provide surrogate markers of early RV remodeling.
OBJECTIVE: To determine whether dynamic 3-dimensional (3D) tricuspid valve (TV) indices are associated with right ventricular (RV)-pulmonary artery (PA) coupling and may serve as surrogate markers of RV remodeling.
DESIGN: Prospective observational cohort study.
SETTING: Operating rooms at a single academic medical center.
PARTICIPANTS: Fifty-three adult patients undergoing cardiac surgery with cardiopulmonary bypass who had undergone intraoperative 3D transesophageal echocardiography and clinically indicated PA catheterization.
INTERVENTIONS: No study-specific therapeutic intervention was performed. Participants underwent standardized intraoperative hemodynamic assessment and offline 3D TV quantification.
MEASUREMENTS AND MAIN RESULTS: RV-PA coupling was quantified using single-beat pressure-volume methods; impaired coupling was defined as an end-systolic elastance (Ees) to effective arterial elastance (Ea) ratio <0.8. The 3D tricuspid analysis measured annular geometry, annular dynamism, and leaflet tethering indices. Seventeen patients (32%) had impaired coupling. Compared to patients with preserved coupling, those with impaired coupling had lower annulus area change (mean, 11.9% ± 5.2% v 15.8% ± 5.9%; p = 0.025) and greater body surface area-indexed tenting volume (mean, 1.04 ± 0.60 mL/m² v 0.72 ± 0.48 mL/m²; p = 0.044). Annulus area change correlated positively with Ees/Ea (R² = 0.96; p < 0.001), whereas indexed tenting volume correlated inversely (R² = 0.95; p < 0.001). Annulus area change <11% and indexed tenting volume >0.7118 mL/m² identified impaired coupling with moderate discrimination.
CONCLUSIONS: Reduced tricuspid annular dynamism and increased leaflet tenting are associated with impaired RV-PA coupling. Dynamic 3D TV metrics may provide surrogate markers of early RV remodeling.