Impact of right ventricular to pulmonary artery coupling in patients undergoing catheter ablation of atrial fibrillation.
Andrea Bonelli, Anna Degiovanni, Angelica Cersosimo, Enrico Guido Spinoni, Manuel Bosco, Gabriele Dell'Era, Antonella Moreo, Benedetta Carla De Chiara,
Cardiology IV. · Department of Thoracic, Heart and Vascular Diseases, Maggiore della Carità Hospital, Novara.
Key points
From the paper's conclusion- In patients undergoing catheter ablation for atrial fibrillation, RV-PA coupling significantly improved after the procedure. Lower baseline TAPSE/PASP was independently associated with atrial fibrillation recurrence, supporting the role of RV-PA uncoupling as a potential marker for postablation risk stratification.
Abstract
AIMS: Right ventricular to pulmonary artery (RV-PA) coupling has emerged as an important determinant of prognosis in heart failure and pulmonary hypertension. However, its role in patients undergoing catheter ablation of atrial fibrillation remains uncertain. This study investigated changes in RV-PA coupling after ablation and its association with atrial fibrillation recurrence. METHODS AND RESULTS: In this multicenter prospective study, 118 patients undergoing ablation of atrial fibrillation were evaluated at baseline and after 3 months using comprehensive clinical and echocardiographic assessment. Atrial fibrillation recurrence was assessed at 1-year follow-up.After 3 months, tricuspid annular plane systolic excursion (TAPSE) increased (22.4 ± 4.1 to 24 ± 3.8, P < 0.001), pulmonary artery systolic pressure (PASP) decreased (29.5 ± 6.6 to 27.9 ± 7.7, P = 0.030), and TAPSE/PASP increased (0.81 ± 0.27 to 0.93 ± 0.29, P < 0.001). At 1 year, atrial fibrillation recurrence occurred in 50/118 patients (42%). Restricted cubic spline analysis demonstrated a significant nonlinear association between TAPSE/PASP and AF recurrence (P for nonlinearity = 0.041). Patients in the lowest TAPSE/PASP tertile (<0.67 mm/mmHg) had a higher risk of atrial fibrillation recurrence at 1 year compared with those in the highest (hazard ratio 2.66, 95% confidence interval 1.31-5.45, P = 0.007). Kaplan-Meier analysis confirmed a higher recurrence rate in the lowest tertile (log-rank P = 0.012). CONCLUSION: In patients undergoing catheter ablation for atrial fibrillation, RV-PA coupling significantly improved after the procedure. Lower baseline TAPSE/PASP was independently associated with atrial fibrillation recurrence, supporting the role of RV-PA uncoupling as a potential marker for postablation risk stratification.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Predictive Value of Left Atrial Coupling Index Applied to Real‐Time Three‐Dimensional Echocardiography for Late Recurrence After Ablation in Patients With Paroxysmal Atrial FibrillationEchocardiography · 2025
- The Stratified Association of Left Atrial Volume Index and Dynamic Change of Pulmonary Arterial Pressure on Prognosis After Catheter Ablation in Patients With Persistent Atrial Fibrillation.Korean circulation journal · 2026
- Prognostic value of a three-dimensional right atrial volumetric-mechanical coupling index in pulmonary arterial hypertension.Heart & lung : the journal of critical care · 2026
- Right ventricular–pulmonary arterial coupling in a community-based cohortEuropean Heart Journal · 2026
- Assessment of RV–PA Coupling in Advanced Heart Failure Using TAPSE×PAAT and Its Association With Functional CapacityEchocardiography · 2026
- Radiofrequency Catheter Ablation of Atrial Fibrillation in Patients with Anomalous Pulmonary Venous Return: A Multicenter Case Series.medRxiv · 2026