Same patient, same total knee arthroplasty, different outcomes? A pilot study comparing conventional vs. OMNIBotics Robotic-Assisted HLS KneetecTM (Corin®).
Galdéric Roblot, Marie Moret, Quentin Seguret, Sofiane Taouli, Bassel Al Hassoun, Olivier Roux, Patrice Mertl, Cecile Laterza,
Service de Chirurgie Orthopédique et Traumatologie, Compiegne-Noyon Hospital, 8 avenue Henri Adnot, Compiegne 60200, France - Service de Chirurgie Orthopédique et Traumatologie, CHU Amiens, 1 rond-point du Pr Cabrol, Picardie, 80054 Amiens Cedex, France. · Service de Chirurgie Orthopédique et Traumatologie, Compiegne-Noyon Hospital, 8 avenue Henri Adnot, Compiegne 60200, France.
Key points
From the paper's conclusion- In this pilot study, RA-TKA was associated with superior frontal alignment and better patient-reported functional outcomes compared to C-TKA. However, given the inherent temporal confounding of the bilateral sequential design and the small sample size, these findings should be interpreted with caution. Further prospective, adequately powered studies are warranted to confirm these results.
Abstract
INTRODUCTION: Total knee arthroplasty (TKA) is a well-established treatment for end-stage knee osteoarthritis. Robotic-assisted TKA (RA-TKA) has emerged over the past decade, enabling patient-specific implantation, precise bone cuts, and intraoperative control of gap balance and alignment. The HLS KneetecTM is a third condyle posterior stabilized TKA, initially designed for implantation using conventional manual instrumentation (C-TKA), and intended for use with an adjusted mechanical alignment. It can now also be implanted with robotic assistance. This pilot study aimed to evaluate the association between RA-TKA versus C-TKA and clinical outcomes in patients with bilateral knee osteoarthritis. MATERIALS AND METHODS: This was a retrospective cohort of patients operated on by primary RA-TKA in a second osteoarthritic knee after contralateral C-TKA. Twenty-two patients constituted their own control group (44 knees). Mean age was 71.9 ± 7.4 years. The mean time between the two procedures was 22 ± 19 months. Primary outcomes measured were limb alignment (hip-knee-ankle (HKA)), range of motion (ROM), and Forgotten Joint Score (FJS) at one year postoperatively. Secondary outcomes included operating time, hospital stay, incision length, blood loss, and radiographic evaluation (femoral mechanical angle (FMA), tibial mechanical angle (TMA), tibial component slope angle (TSA), patellar tilt angle (PTA), and femoral axial rotation angle (FARA)). RESULTS: RA-TKA was associated with an HKA angle significantly closer to the target (177.9° vs. 175.3°, p = 0.012), with higher flexion (+7°, p = 0.032) and a higher FJS (+13.9 points, p < 0.001). Operating time was longer in the RA-TKA group (+19.5 min, p = 0.004), while hospital stay, blood loss, and incision length did not differ significantly between groups. Radiographically, RA-TKA was associated with reduced femoral valgus (FMA -1.3°, p = 0.001), with no significant differences in TMA or TSA. Patellar tilt was similar, whereas femoral external rotation was increased with RA-TKA (+1.1°, p = 0.0006). CONCLUSION: In this pilot study, RA-TKA was associated with superior frontal alignment and better patient-reported functional outcomes compared to C-TKA. However, given the inherent temporal confounding of the bilateral sequential design and the small sample size, these findings should be interpreted with caution. Further prospective, adequately powered studies are warranted to confirm these results.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparison of Conventional Total Knee Arthroplasty Versus Robotic-Assisted Total Knee Arthroplasty in Primary Osteoarthritis of the Knee: A Prospective Comparative Pilot Study.Cureus · 2026
- Robotic-assisted surgery and functional alignment in total knee arthroplasty: the RASKAL registry-nested 2 × 2 factorial randomized trial.PubMed · 2026
- Improved surgical accuracy in total knee arthroplasty using the ROSA® knee system: A randomised‐controlled unblinded trialKnee Surgery Sports Traumatology Arthroscopy · 2025
- Functional alignment with robotic-assisted total knee arthroplasty is associated with reduced early postoperative pain and alignment outliers compared to mechanical alignment with conventional total knee arthroplasty: a prospective cohort study.SICOT-J · 2026
- Radiographic Accuracy and Consistency of Implant Placement Using the ROSA® Knee System in Robotic-Assisted Total Knee Arthroplasty: A Prospective AnalysisLife · 2026
- Effect of Prosthesis Selection on Gap Balancing in Robotic-Assisted Cruciate-Retaining and Posterior-Stabilized Total Knee Arthroplasty: A Prospective Randomized Controlled Trial.The Journal of arthroplasty · 2026