DermaCal: Reliability Benchmarking and Quality-Aware Confidence Calibration of Dermatology AI under Real-World Image-Quality Degradation
Ning Yang
Key points
From the paper's conclusion- These results support quality-aware calibration and low-quality sample deferral for risk-aware teledermatology AI deployment.
Abstract
In real-world teledermatology, blur, noise, illumination variation, and compression can degrade classification performance and disrupt the alignment between predictive confidence and empirical accuracy, increasing the risk of high-confidence errors. To address the limited evaluation and calibration of dermatology Artificial Intelligence (AI) under such conditions, this study propose DermaCal. The framework constructs a benchmark with six degradation types at three severity levels and evaluates ResNet-50, EfficientNet-B0, ViT-B/16, and DINOv2-B in terms of classification performance, calibration, and clinical reliability. This study further introduces Quality-Aware Confidence Calibration (QACA), a post-hoc method that uses robustly normalized Blind/Referenceless Image Spatial Quality Evaluator (BRISQUE) scores to generate sample-specific temperatures and defer predictions for extremely low-quality images without retraining the classifier. Experiments show that image-quality degradation impairs both classification and calibration, with brightness shift causing the largest deterioration. Under severe degradation, QACA achieves the lowest calibration error among the evaluated methods and reduces high-confidence error rates under moderate and severe degradation from 8.89% and 8.53% to 1.28% and 0.50%, respectively. These results support quality-aware calibration and low-quality sample deferral for risk-aware teledermatology AI deployment.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Discrimination transfers but calibration does not across fundus cameras in diabetic retinopathy screeningScientific Reports · 2026
- Trustworthy DINOv2-based skin lesion classification with uncertainty quantification and robust learning from limited medical imagesDiscover Computing · 2026
- Calibrated per-pixel uncertainty for low-dose paediatric chest-radiograph denoising at no fidelity costmedRxiv · 2026
- DermaGPT a federated multimodal framework with a meta learned trust function for interpretable dermatology diagnosticsScientific Reports · 2026
- Calibrated Confidence and Confidence-Stratified Triage for Diabetic Retinopathy Severity Grading: A Class-Imbalance-Aware Deep Learning Study on the DDR Dataset.Bioengineering (Basel, Switzerland) · 2026