E3S Web of Conferences

Digital image correlation assessment of masonry infill-frame interaction in reinforced-concrete frames under in-plane loading

Ismail Layadi, Jean Patrick Plassiard, Olivier Plé

Key points

From the paper's conclusion
  • Specimens were tested under monotonic and load/unload lateral loading while a digital image correlation (DIC) system tracked the full strain field.

Abstract

The contribution of masonry infill to the in-plane response of reinforced concrete (RC) frames is strongly governed by the construction sequence, yet the infill-frame interface is rarely resolved experimentally with full-field measurements. This paper reports quasi-static tests on four half-scale, single-bay single-storey RC frames – two bare and two infilled with double-leaf fired-clay brick walls built after the frame, as is common practice in Algeria. Specimens were tested under monotonic and load/unload lateral loading while a digital image correlation (DIC) system tracked the full strain field. Infilling raised the lateral strength by a factor of about 2.6-2.7 (from 76 kN to 197-207 kN) and the initial stiffness by 4.4-5.3 times, but reduced the displacement ductility from 4.8-5.6 to 4.0-4.3. Bare frames failed in flexure at the beam-column joints, whereas infilled frames developed the classical diagonal strut and crushing of the upper corner. DIC revealed that infill-frame detachment, not panel cracking, was the first irreversible event, with significant interface sliding developing near 75 % of peak load and confining monolithic behaviour to the lower corners of the panel. Load/unload envelopes matched the monotonic curves, indicating good repeatability but limited ability to reproduce cyclic energy dissipation.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers