  • Compared with a code-compliant baseline, it reduced the overall heat-loss coefficient by 54.9%, annual heating demand by 58.5%, and envelope-related carbon emissions by 48.0%, while the final bidirectional blower-door test achieved n50 = 0.55 h-1 and the critical floor-line interior surface temperature remained at 18.2 degC.

Abstract

This study evaluates a prefabricated envelope system for ultra-low-energy buildings under Qingdao's cold, humid, salt-laden coastal conditions. A representative twelve-storey residential model was assessed through junction simulation, annual energy calculation, condensation-risk analysis, and tolerance sensitivity tests. The system combines precast concrete sandwich panels, continuous external insulation, low-conductivity connectors, triple glazing, and airtight joints. Compared with a code-compliant baseline, it reduced the overall heat-loss coefficient by 54.9%, annual heating demand by 58.5%, and envelope-related carbon emissions by 48.0%, while the final bidirectional blower-door test achieved n50 = 0.55 h-1 and the critical floor-line interior surface temperature remained at 18.2 degC. The results provide a replicable design and quality-control route for coastal cold-region construction.