RSC advances

Kaolin-derived Cu(ii)-doped zeolite supported on nickel foam for electrochemical paracetamol detection.

Endazenaw Bizuneh Chemere, Chernet Beraso Jigso, Washington Mhike, Mapula Lucey Mavhungu, Winny Kgabo Maboya, Makgwane Peter Ramashadi, Abolanle Saheed Adekunle

Institute for Catalysis and Energy Solutions, College of Science, Engineering and Technology (CSET), University of South Africa (UNISA) Florida 1709 Johannesburg South Africa chemeeb@unisa.ac.za maboywk@unisa.ac.za makgwpr@unisa.ac.za adekuas@unisa.ac.za. · Department of Chemistry, College of Natural and Computational Sciences, Dilla University Dilla Ethiopia cberaso22@gmail.com.

Key points

From the paper's conclusion
  • A kaolin-derived Cu(ii)-doped zeolite (Cu-Z1) was synthesized through metakaolin activation, alkaline crystallization, and subsequent Cu2+ ion exchange, and immobilized on nickel foam (Cu-Z1/NiF) for electrochemical determination of paracetamol.

Abstract

A kaolin-derived Cu(ii)-doped zeolite (Cu-Z1) was synthesized through metakaolin activation, alkaline crystallization, and subsequent Cu2+ ion exchange, and immobilized on nickel foam (Cu-Z1/NiF) for electrochemical determination of paracetamol. The synthesized materials were characterized using Fourier-transform infrared spectroscopy (FTIR), X-ray diffraction (XRD), scanning electron microscopy coupled with energy-dispersive X-ray spectroscopy (SEM/EDS), X-ray photoelectron spectroscopy (XPS), and thermogravimetric/differential thermogravimetric analysis (TGA/DTGA). The characterization results confirmed preservation of a ZSM-5-type aluminosilicate framework following Cu(ii) incorporation, with accompanying changes in crystallinity, morphology, and surface chemical environment. Electrochemical measurements demonstrated enhanced paracetamol oxidation at Cu-Z1/NiF compared with bare nickel foam and undoped Z1/NiF, giving an anodic peak current of 75.69 µA, a midpoint potential of 355 mV, and reduced charge-transfer resistance. Under optimized conditions, differential pulse voltammetry (DPV) showed a linear response over 5-100 µM paracetamol, with a detection limit of 0.3926 µM, sensitivity of 2.0456 µA µM-1 cm-2, and R 2 = 0.9971. The sensor exhibited good selectivity toward paracetamol in the presence of dopamine, uric acid, and glucose, with repeatability below 0.8% RSD. It retained 95.8% of its initial response after 20 days. Analysis of commercial paracetamol tablets produced recoveries of 95.91-99.29%, demonstrating the applicability of the Cu-Z1/NiF sensor for pharmaceutical paracetamol determination.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Kaolin-derived Cu(ii)-doped zeolite supported on nickel foam for electrochemical paracetamol detection — Science Skim