Development of Co and Cu-based metal-organic frameworks for electrochemical sensing of Pb ions and paracetamol.
Farzana Akter, Sanjida Khan, Suravi Islam, A M Sarwaruddin Chowdhury, Samina Ahmed, Sumaya F Kabir, Md Sahadat Hossain
Department of Applied Chemistry and Chemical Engineering, University of Dhaka Dhaka-1000 Bangladesh sumaya.kabir@du.ac.bd. · Institute of Leather Engineering and Technology, University of Dhaka Dhaka Bangladesh.
Key points
From the paper's conclusion- For a heavy metal (Pb), the estimated LOD and LOQ were 0.09 and 0.31 ppm, respectively.
Abstract
The present study investigates charge-transfer activity in electrochemistry using a metal-organic framework (MOF) to detect pharmaceutical contaminants (organic substances) along with toxic metals (inorganic pollutants). These contaminants constitute a major threat to human health as well as to the environment because of their persistence, adverse effects, and bioaccumulation. The MOFs (Cu MOF, Cu-Co MOF, and Co MOF) were produced via solvothermal synthesis. They were analyzed by a variety of methods, such as X-ray diffraction (XRD) and Fourier transform infrared (FTIR) spectroscopy. The range of crystalline size of the synthesized MOFs using the Debye-Scherrer equation was 80-92 nm. The thermal resistance of the MOFs was examined using thermogravimetric analysis (TGA). In this study, a bimetallic Cu-Co MOF-modified electrode was developed and systematically evaluated as an electrochemical sensing material. In comparison with the monometallic Cu MOF and Co MOF, the Cu-Co MOF exhibited enhanced electrochemical performance, which could be attributed to the synergistic effect of the two metal centers. Furthermore, the Cu-Co MOF served as a dual-electrode system for detecting two analytes (paracetamol and Pb), highlighting its potential as a versatile sensing platform for pharmaceutical and environmental monitoring. For paracetamol, the limit of detection (LOD) and limit of quantitation (LOQ), based on the oxidation current, were 1.98 and 6.59 ppm, respectively. Similarly, based on the reduction current, the calculated LOD and LOQ were 0.20 ppm and 0.68 ppm, respectively. For a heavy metal (Pb), the estimated LOD and LOQ were 0.09 and 0.31 ppm, respectively.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Cu‐Metalated Schiff‐Base‐Functionalized Iron‐Based Metal–Organic Framework for Simultaneous Electrochemical Detection of 4‐Aminophenol and AcetaminophenChemNanoMat · 2026
- Recent research on MOF and COF-based materials for heavy metal ion detectionMicrochemical Journal · 2025
- Recent progress in the electrochemical detection of environmental pollutants using MOFs and COFs.Analytical methods : advancing methods and applications · 2026
- A cobalt MOF-derived electrochemical platform for dual detection of glucose and hydrogen peroxideElectrochimica Acta · 2026
- Electrocatalytic Sensing of Para-Hydroxybenzoic Acid Using Metalloporphyrin Microporous Polymers: Effect of the Central MetalJournal of Inorganic and Organometallic Polymers and Materials · 2026
- A novel cobalt-based MOF for simultaneous removal of Pb(ii) and Congo red from real textile wastewater: synergistic adsorption behavior and mechanistic insights.RSC advances · 2026