Advances in salivary cortisol monitoring for healthcare applications.
Ganden W X Kok, Emily Ortega, Michelle Z L Kee, Leon C Z Chan
School of Biological Sciences (SBS), Nanyang Technological University (NTU) Singapore 637551 Singapore kokganden@gmail.com. · School of Humanities and Behavioural Sciences, Singapore University of Social Sciences Singapore 599494 Singapore.
Key points
From the paper's conclusion- Across platforms, very low limits of detection do not by themselves establish suitability for salivary monitoring; physiologically relevant range coverage, authentic-saliva validation, comparison with reference methods and reproducibility are also required.
Abstract
Cortisol is a dynamic endocrine biomarker whose concentration varies with circadian timing, acute stressors, medication, sampling conditions and population characteristics. Saliva provides a non-invasive matrix for repeated measurement of the unbound hormone fraction and is compatible with decentralised point-of-care formats, but salivary cortisol should be interpreted as an adjunctive physiological measure rather than a standalone diagnostic test for psychiatric disorders. This review compares biological sampling matrices and critically evaluates lateral-flow immunoassays, electrochemical, surface-plasmon-resonance and quantum-dot-based cortisol sensors according to recognition chemistry, transduction mechanism, analytical range, sample matrix, validation level and translational readiness. Competitive lateral-flow assays offer rapid, low-cost and discrete measurements, whereas wearable electrochemical and microneedle platforms may support higher-frequency monitoring but face challenges in sample availability, biofouling, calibration drift and long-term stability. Across platforms, very low limits of detection do not by themselves establish suitability for salivary monitoring; physiologically relevant range coverage, authentic-saliva validation, comparison with reference methods and reproducibility are also required. Future progress will depend on standardised collection protocols, selective recognition chemistry, robust digital readout, circadian-aware interpretation and independent clinical validation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Advances in Electrochemical Nanobiosensors for Noninvasive Stress Biomarker DetectionSensors · 2025
- Wired for stress: Advances in electrochemical biosensors for monitoring of cortisol and catecholamines via wearable and point-of-care platformsTrAC Trends in Analytical Chemistry · 2026
- Cortisol Dynamics at High Temporal Resolution For Wearable Biosensor ResearchAdvanced Sensor Research · 2026
- A multimodal wearable microfluidic platform for in situ sweat cortisol monitoring with a NiHCF-enabled molecularly imprinted electrochemical sensor.Biosensors & bioelectronics · 2026
- Wearable Microfluidic Chip Integrated with Chrono-Sampling for Cortisol Detection in Sweat.Analytical chemistry · 2026
- AI-Driven Dual-Graphene Near-Infrared SPR Biosensor for Non-Invasive Salivary Cortisol Monitoring.Biosensors · 2026