Cortisol Dynamics at High Temporal Resolution For Wearable Biosensor Research
Munia Ferdoushi, Tess Billings, Wenxin Cai, Yasser Khan
Key points
From the paper's conclusion- We further examine commonly used laboratory stress‐induction paradigms, such as the Trier Social Stress Test, Cold Pressor Test, Maastricht Acute Stress Test, cognitive stressors, and multicomponent stress protocols, with an emphasis on their applicability to wearable cortisol sensor development.
Abstract
Cortisol is a dynamic endocrine biomarker regulated by hypothalamic–pituitary–adrenal (HPA) axis activity, and plays a central role in circadian regulation and physiological stress responsiveness. This review summarizes key aspects of cortisol dynamics, including circadian rhythms, modulatory factors, dysregulation, and acute and chronic stress responses. We further examine commonly used laboratory stress‐induction paradigms, such as the Trier Social Stress Test, Cold Pressor Test, Maastricht Acute Stress Test, cognitive stressors, and multicomponent stress protocols, with an emphasis on their applicability to wearable cortisol sensor development. Particular attention is given to experimental design considerations, including the choice of sampling matrix, sensor‐influenced temporal resolution, and acquisition frequency, as these parameters critically influence the interpretation of cortisol fluctuations and define the performance requirements of sensing platforms. To complement the literature review, we additionally report preliminary observations from a pilot study involving three healthy adult participants. The pilot experiments explore the feasibility of selected stress‐induction protocols for eliciting measurable stress responses using a dense temporal sampling protocol. By integrating insights from prior studies with our pilot observations, we highlight methodological considerations for capturing physiologically meaningful cortisol responses to stress, with a specific focus on stress‐induced dynamics and the temporal resolution necessary for continuous or near‐continuous monitoring.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Advances in salivary cortisol monitoring for healthcare applications.RSC advances · 2026
- Wired for stress: Advances in electrochemical biosensors for monitoring of cortisol and catecholamines via wearable and point-of-care platformsTrAC Trends in Analytical Chemistry · 2026
- Integrated machine-learning-assisted wearable platform for stress state assessment based on sweat cortisol and multimodal physiological biosensing.Biosensors & bioelectronics · 2026
- Advances in Electrochemical Nanobiosensors for Noninvasive Stress Biomarker DetectionSensors · 2025
- Wearable Microfluidic Chip Integrated with Chrono-Sampling for Cortisol Detection in Sweat.Analytical chemistry · 2026
- Human Sweat Cortisol Versus Blood and Saliva: Quantitative Interpretation.Methods and protocols · 2026