Assessment and development of decontamination strategies for fentanyl and fentanyl analogues.
Mikaela M Bazley, Avril A B Robertson, Joanne T Blanchfield
School of Chemistry and Molecular Biosciences, The University of Queensland St Lucia QLD 4072 Australia j.blanchfield@uq.edu.au https://www.scmb.uq.edu.au +61 7 3365 3622.
Key points
From the paper's conclusion- This work presents a new approach to assessing fentanyl decontamination efficacy involving upscaling the reaction between fentanyl (∼15 mg) and the decontaminant, and fractionation of the reaction mixture by medium pressure liquid chromatography (MPLC).
Abstract
Over the past decade, fentanyl and fentanyl analogues have pervaded the illicit drug market and are encountered with growing frequency by law enforcement, HazMat and other first-responder groups. Several studies have addressed the removal of fentanyl from surfaces. However, significantly fewer have focussed efforts on the chemical breakdown of this class of pharmaceuticals. This work presents a new approach to assessing fentanyl decontamination efficacy involving upscaling the reaction between fentanyl (∼15 mg) and the decontaminant, and fractionation of the reaction mixture by medium pressure liquid chromatography (MPLC). This method allowed the identification of surfactant-formulated sodium dichloroisocyanurate as a decontaminant that achieves molecular destruction of fentanyl, rather than simply conversion to the N-oxide of the compound achieved by most recommended degradation methods. The upscaled decontamination assessment approach developed and described herein represents an important reform in decontamination methodology by providing a wider lens through which to assess decontamination efficacy.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Trends in Fentanyl Adulteration From Rapid Drug Analysis and Research (RaDAR) Drug Checking Samples, January 2024 to June 2026.Drug testing and analysis · 2026
- 96-Sample Parallel BioSPME-DART-MS Platform for Rapid Screening of Fentanyl and its Analogues in Biofluids.Analytical chemistry · 2026
- Drug trash to treasure: quantitative mass spectrometric analysis of residual drugs from used lateral flow immunoassay test strips and syringe plungersHarm Reduction Journal · 2026
- Estimating the daily milligrams of morphine equivalent of illicit fentanyl use in Los Angeles: Clinical and epidemiological implicationsDrug and Alcohol Dependence · 2026
- The penetration of the Novichok nerve agent A-234 in a human skin model and the assessment of several decontamination procedures.Toxicology letters · 2026
- B-399 Lessons Learned: Reducing False-Positive Fentanyl Screens in a Pediatric Hospital Through Assay SelectionClinical Chemistry · 2026