Copper oxide nanoparticle/stainless steel hybrid structures for non-enzymatic glucose detection.
Andrei Alaferdov, Bruna M Hryniewicz, Kelly T C Thomaz, Jordelson A A Junior, Carolina C P Nunes, Fernando I L Leite
Center for Semiconductor Components and Nanotechnologies, Universidade Estadual de Campinas Campinas SP 13083-870 Brazil laferd@unicamp.br. · Department of Physical Chemistry, Institute of Chemistry, Federal University of Bahia Salvador Bahia 40170-115 Brazil.
Key points
From the paper's conclusion- The sensing platform, supported by a flexible polyimide (PI) substrate, consists of a stainless steel (SS) thin film-characterized by a non-flat granular morphology (average grain size ∼364 nm)-decorated with copper oxide nanoparticles (NPs).
Abstract
The global prevalence of diabetes necessitates the development of cost-effective, durable, high-performance platforms for glucose monitoring. In this work, a flexible hybrid architecture for non-enzymatic glucose sensing is reported. The sensing platform, supported by a flexible polyimide (PI) substrate, consists of a stainless steel (SS) thin film-characterized by a non-flat granular morphology (average grain size ∼364 nm)-decorated with copper oxide nanoparticles (NPs). Fabricated via DC sputtering, followed by optimized thermal oxidation (310 °C for 2 h), the hybrid structure exhibits a distinct catalytic interface with a significant fraction (∼40%) of the glucose-sensitive polycrystalline CuO phase, as estimated by XPS and supported by SAED analysis. Structural characterization via HRSEM, HRTEM, and SAED reveals a uniform distribution of predominantly polycrystalline NPs (average size ∼11 nm) across the SS film, resulting in a high electrical conductivity of 6.7 kS cm-1. Electrochemical analysis demonstrates a sensitivity of 831 µA cm-2 mM-1 within a linear detection range of 1-5 mM and a limit of detection of 0.13 mM, determined from a linear calibration over the 1-5 mM range. The scalability of the fabrication process, combined with the structural integrity and electrochemical performance, positions the SS film/Cu NP oxide hybrid as a compelling, cost-effective alternative to noble-metal-based sensors for lab-on-chip glucose monitoring with integrated alkaline sample conditioning and, following further adaptation of the electrode and device architecture, a potential wearable medical diagnostic device.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Scalable Fabrication of Stainless Steel-CuO Hybrid Nanostructured Electrodes for Nonenzymatic Glucose Sensing.ACS omega · 2026
- Systematic Nonenzymatic Glucose Detection Using Hydrogel-Protected Ag–Cu/MWCNTs NanocompositesACS Omega · 2025
- Nanostructured copper/cobalt tungstate/poly(aniline-co-pyrrole) hybrid electrode for high-performance enzymatic glucose biosensing.Talanta · 2026
- CuS/PANI/GR conductive network with enhanced interfacial charge transfer for non-enzymatic glucose sensing.Analytical methods : advancing methods and applications · 2026
- Flexible Non-Enzymatic Glucose Sensors via Electrospray Reduction of Copper Nanoparticles on Laser-Induced Graphene.ACS applied materials & interfaces · 2026
- pH-modulated wet chemical synthesis of copper oxide nanostructures.Nanotechnology · 2026