Lab on a chip

Lab-on-a-capillary: instrument-free compartmentalization using photopatterned hydrogel rings embedded inside a glass capillary for amplified bioassays.

Yimin Yang, Muhammad Usman Akhtar, Mehmet Akif Sahin, Yibo Huang, Liusu Wang, Xinpei Song, Ghulam Destgeer

Control and Manipulation of Microscale Living Objects, Center for Translational Cancer Research (TranslaTUM), Munich Institute of Biomedical Engineering (MIBE), Munich Institute of Integrated Materials, Energy and Process Engineering (MEP), Department of Electrical Engineering, School of Computation, Information and Technology (CIT), Technical University of Munich (TUM), Einsteinstraße 25, Munich 81675, Germany. ghulam.destgeer@tum.de. · Robotics and Microsystems Center, School of Mechanical and Electrical Engineering, Soochow University, Suzhou, 215000, China.

Key points

From the paper's conclusion
  • Here, we develop a lab-on-a-capillary (LabCap) platform that integrates photopatterned hydrogel rings within a glass capillary using a reconfigurable stop-flow lithography system.

Abstract

Sensitive and low-cost protein biomarker detection is critical for disease diagnosis. Advanced microfluidic systems can generate miniature reaction compartments for a high-sensitivity assay. However, these platforms often require external instruments, skilled operators, and complex setups. Here, we develop a lab-on-a-capillary (LabCap) platform that integrates photopatterned hydrogel rings within a glass capillary using a reconfigurable stop-flow lithography system. During sample loading and unloading steps, nanoliter-scale aqueous droplets (torodrops) are spontaneously formed around the hydrogel rings, creating isolated reaction compartments without the need for external instruments or an immiscible oil phase. The LabCap platform enables detection of clinically relevant biomarkers, including C-reactive protein (CRP) and N-terminal pro-B-type natriuretic peptide (NT-proBNP). By adjusting the incubation protocol, the detection performance can be tuned to meet different analytical requirements. A 16 min periodic medium exchange protocol yielded calculated limits of detection of 1.3 ng mL-1 for CRP and 1.8 ng mL-1 for NT-proBNP, whereas static incubation yielded 0.5 ng mL-1 for both biomarkers after 1 h and 0.14 ng mL-1 for CRP at a matched 16 min incubation. In addition, LabCap offers practical advantages, including a low consumable material cost for fabricating one device (<€1), low reagent consumption (<100 μL per assay step), and minimal wash-buffer usage (1 mL). These results demonstrate that LabCap is a simple, cost-effective, and versatile platform for compartmentalized biomarker detection.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Lab-on-a-capillary: instrument-free compartmentalization using photopatterned hydrogel rings embedded inside a glass capillary for amplified bioassays — Science Skim