Lab-on-a-capillary: instrument-free compartmentalization using photopatterned hydrogel rings embedded inside a glass capillary for amplified bioassays.
Yimin Yang, Muhammad Usman Akhtar, Mehmet Akif Sahin, Yibo Huang, Liusu Wang, Xinpei Song, Ghulam Destgeer
Control and Manipulation of Microscale Living Objects, Center for Translational Cancer Research (TranslaTUM), Munich Institute of Biomedical Engineering (MIBE), Munich Institute of Integrated Materials, Energy and Process Engineering (MEP), Department of Electrical Engineering, School of Computation, Information and Technology (CIT), Technical University of Munich (TUM), Einsteinstraße 25, Munich 81675, Germany. ghulam.destgeer@tum.de. · Robotics and Microsystems Center, School of Mechanical and Electrical Engineering, Soochow University, Suzhou, 215000, China.
Key points
From the paper's conclusion- Here, we develop a lab-on-a-capillary (LabCap) platform that integrates photopatterned hydrogel rings within a glass capillary using a reconfigurable stop-flow lithography system.
Abstract
Sensitive and low-cost protein biomarker detection is critical for disease diagnosis. Advanced microfluidic systems can generate miniature reaction compartments for a high-sensitivity assay. However, these platforms often require external instruments, skilled operators, and complex setups. Here, we develop a lab-on-a-capillary (LabCap) platform that integrates photopatterned hydrogel rings within a glass capillary using a reconfigurable stop-flow lithography system. During sample loading and unloading steps, nanoliter-scale aqueous droplets (torodrops) are spontaneously formed around the hydrogel rings, creating isolated reaction compartments without the need for external instruments or an immiscible oil phase. The LabCap platform enables detection of clinically relevant biomarkers, including C-reactive protein (CRP) and N-terminal pro-B-type natriuretic peptide (NT-proBNP). By adjusting the incubation protocol, the detection performance can be tuned to meet different analytical requirements. A 16 min periodic medium exchange protocol yielded calculated limits of detection of 1.3 ng mL-1 for CRP and 1.8 ng mL-1 for NT-proBNP, whereas static incubation yielded 0.5 ng mL-1 for both biomarkers after 1 h and 0.14 ng mL-1 for CRP at a matched 16 min incubation. In addition, LabCap offers practical advantages, including a low consumable material cost for fabricating one device (<€1), low reagent consumption (<100 μL per assay step), and minimal wash-buffer usage (1 mL). These results demonstrate that LabCap is a simple, cost-effective, and versatile platform for compartmentalized biomarker detection.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- MEC-BioSense: Material-Encoded Capillary Biointerface for Autonomous Whole-Blood Biomarker Sensing.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026
- One-Step Self-Assembling Lipopolymer Coatings Enable Direct Longitudinal Biosensing in Native Biological MatricesarXiv · 2026
- A Self-Confined Rotational Hydrogel Chemiluminescence Motor Array for Rapid and Sensitive Detection of Bladder Cancer Biomarkers.Analytical chemistry · 2026
- A bioorthogonal capture-and-release platform for isolation of nanoparticle protein coronas.Journal of materials chemistry. B · 2026
- Multimodal Sensitivity Enhancement of Binding-based Diagnostic Assays Using Functional HydrogelsbioRxiv · 2026
- A Droplet-Free and Oil-Free Microfluidics Based on Self-Pumping Hydrogel for Point-of-Care Multiplex Digital Nucleic Acid DetectionAnalytical Chemistry · 2026